Maintenance & servicing – LG B-VENT GAS GC3 User Manual

Page 17

Advertising
background image

17

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Maintenance & Servicing

m

aintenanCe

C

heCklist

Should Only Be Performed by a Qualified Service Techni-

cian.

Caution: Label all wires prior to disconnection when

servicing controls. Wiring errors can cause improper

and dangerous operation. Verify proper operation after

servicing.

1. Annual inspection should be made and the following

checks performed:

a) With unit cool, remove glass and inspect burner for dirt,

soot, and lint accumulations and remove if necessary.

If excessive soot accumulation is present on burner,

have a qualified serviceman adjust burner for proper

combustion.

b) Clean any deposits from inside glass with gas fireplace

glass cleaner. NEVER attempt to remove or clean glass

when the unit is hot.

c) Check that chimney and its outlet are open and free from

soot, blockage, or debris.

d) Inspect the pilot system for proper flame. See instruc-

tions on page 15.

e) Check the Millivolt system as per Table 4 on page 16.

f) The appliance area must be kept clear and free of com-

bustible materials, gasoline, and other flammable vapors

and liquids.

g) Check glass gaskets once a year. Gaskets must be tight.

Replace if necessary.

. The viewing glass should be cleaned periodically (see

Glass Maintenance).

g

lass

m

aintenanCe

Cleaning: When cool, the glass may be cleaned with a clean,

soft cloth and Windex. For cleaning white condensation from

the interior glass, use KEL KEM gas fireplace glass cleaner

available from your insert dealer. Use of caustic or abrasive

cleaners may damage the glass. DO NOT operate the insert

with broken glass. DO NOT clean door or glass when hot. DO

NOT abuse the glass door by striking or slamming it shut.

DO NOT use substitute materials if replacing the glass. DO

NOT spray commercial glass cleaner with ammonia on the

door and glass gasket as it may dissolve the gasket glue.

Replacement: The glass in the insert door cannot be replaced

separately. Should the glass be damaged, the entire glass,

gasket, and metal frame assembly must be replaced as a

unit. This replacement glass assembly is available from your

Lennox Hearth Products dealer. The glass is neo-ceramic

and alternative types must not be used.

WARNING: Do not operate appliance with the glass panel

removed, cracked, or broken. Do not remove glass door

while the insert is hot. Replacement of the glass door

should be done by a qualified service technician.

g

lass

d

oor

r

emoval

(refer to Figures 0a and 0b)

Caution: Do not slam or strike glass door or damage

may occur.

Do not remove the glass door while the insert is hot. Open

both latches on the right and left side of the door (they

are centered on the sides of the front door - see Figure

0a). With the latches released, rotate the catch part of

each latch outward away from the front door. The door

will pivot toward you from the top (hinging from the bottom

as shown in Figure 0b). On the bottom of the door there

are tabs that slide into slots on the firebox. Disengage the

tabs on the door from the slots on the firebox by lifting up

on the door until it stops and slide the door all the way to

the left. You can then remove the door straight out from

the slots. To reinstall door reverse the steps above.

Figure 0a

Figure 0b

Open the top door latches by pulling them forward and up.

Lift the glass door up and off the lower spring latch

Side Door Latches

Door

Lower Front Door Tabs

Advertising