0 using access control – LCD Digital DGP2-641 User Manual

Page 12

Advertising
background image

12 System Manager’s Manual

Option [8]: Access to Armed Access Control Doors
When option [8] is enabled, the Access Control Card can be used to open an armed Access Control Door. When a
valid Access Control Card is presented to a reader that is assigned to a zone and the zone is armed, access will be
granted and the Entry Delay will begin. When option [8] is ON, extra security is provided since a user must enter a
User Access Code to disarm the area.

For option [8] to function in the ON position, option [5] “Arm Only” in the User Options (refer
to section 5.4 on page 11) and option [2] “ Disarming with Access Card” in the Access Control
User Options (refer to section 5.5 on page 11) must be disabled.

6.0 USING ACCESS CONTROL

6.1

ENTERING & EXITING

Depending on how your system is installed, there are various ways to enter and exit Access Control Doors:

1. Present your Access Control Card to the reader. The system will verify that the

card is allowed access according to its assigned Access Level and Schedule. If it
is accepted, the system will unlock the door. The reader’s light can be pro-
grammed by the installer to turn green or extinguish briefly to indicate that the
door can be opened. The reader can also be programmed by the installer to audi-
bly inform you that the door can be opened.

2. When the motion detector detects movement (Request for Exit), it will unlock the

door to permit passage from inside.

3. Enter your User Access Code on a keypad and press [

ACC

].

4. If the Access Control Door is on a “Door Unlocked Schedule”, you may be able to

open Access Control Doors without using a User Access Code or an Access Con-
trol Card. Depending on the door’s programming, the door can remain unlocked
during the entire programmed schedule or the door can unlock once a valid
Access Control Card is presented to the reader during the schedule and then will
remain unlocked for the remainder of the schedule.

6.2

ARMING AND DISARMING WITH CARD

6.2.1

A

RMING

WITH

C

ARD

An Access Control Card can be programmed to arm areas assigned to the door when it is presented to
the reader (door) twice within approximately 5 seconds without opening the door.
The Access Control card must be:

• presented to a door during its assigned Schedule (refer to step 8 in Figure 5.1 on page 9).
• presented to a door within its assigned Access Level (refer to step 8 in Figure 5.1 on page 9).
• programmed to allow arming (options [4] and [5] in section 5.5 on page 11).
• assigned to all areas that are assigned to the Access Control Door (refer to step 7 in Figure 5.1 on page 9), or

assigned to at least one of the areas assigned to the Access Control Door depending on how your Installer
has programmed the Access Control Door.

6.2.2

D

ISARMING

WITH

C

ARD

To disarm and unlock an Access Control Door when the area assigned to it is armed, present your Access
Control Card to the reader (door).

The Access Control card must be:

• presented to a door during its assigned Schedule (refer to step 8 in Figure 5.1 on page 9).
• presented to a door within its assigned Access Level (refer to step 8 in Figure 5.1 on page 9).
• programmed to allow disarming (option [2] in section 5.5 on page 11).
• assigned to all areas that are assigned to the Access Control Door (refer to step 7 in Figure 5.1 on page 9), or

assigned to at least one of the areas assigned to the Access Control Door depending on how your Installer
has programmed the Access Control Door.‘

Advertising