Ribbon drive service check, Ribbon, Ribbon drive service check” on – Lexmark 4227-X00 User Manual

Page 53

Advertising
background image

2-30

Service Manual

4227-X00

Ribbon Drive Service Check

In normal operation, the ribbon knob rotates counterclockwise
whenever the carrier moves to the left.

FRU/Symptom

Action

1

Ribbon Drive
Gear Train

Remove and inspect the ribbon. Make sure the
knob turns with even, moderate force and the
ribbon feeds correctly.

Inspect the gear train from the ribbon motor to
the ribbon drive post.

Check the

“Printhead-to-Platen Gap

Adjustment” on page 4-2

.

2

Ribbon Motor

If printing seems normal, but the ribbon is not
moving, remove the ribbon and turn power on.

The ribbon drive post should turn several times
during POST. Disconnect the ribbon motor
connector CN19 from the main logic board.

The winding resistance should be
118 ohms ±

5 between pins:

1 and 5, 3 and 5, 2 and 6, 4 and 6.

Pin 5 should show an open circuit to pins 2, 4
and 6. Pin 6 should show an open circuit to
pins 1, 3, and 5.

Advertising