Figure 2 – Liebert CHALLENGER 3000 User Manual

Page 12

Advertising
background image

Operation with Advanced Microprocessor Controls

4

Figure 2

Advanced microprocessor (A) control for Challenger 3000

72°F 50%RH

Cooling
Dehumidifying

No Alarms Present

Status Alarm Data

Active Alarms

Operating Status
Alarm History Log

Run Hours Log

Setpoint Password

Setup Password

Change Password

View

Setpoints

Run

Diagnostics

Change

Password

View Setpoints

Temp Setpoint
Sensitivity

Hum Setpoint

Sensitivity
High Temp

Alarm

Lo Temp Alarm

High Hum Alarm
Lo Hum Alarm

Setup

System

15-APR-2004 09:30:00

ENTER to change
ESCape to exit

Date and Time

75°F 59%RH
Cooling

Dehumidifying
No Alarms Present

Status Display

Active

Alarms

Operating

Status

Alarm

History Log

Run

Hours Log

Analog

Sensors

DX Cool

%

Heat

%

Econo Cool

%

CW Valve

%

DX Deh / Hum

Operating Status

Comp

GLYCOOL** or CW Coil**

Fan
Hum

RH1

RH2

Run Hours Log

Main Menu

Status/Alarm Data
Setpoints/Setup

Date and Time

Status Display

Standard Alarms

Humidifier Problems
High Head Pressures

Change Filter

Loss of Air Flow

High Temperature

Low Temperature

High Humidity
Low Humidity

Short Cycle

Low Suction Pressure
Compressor Overload

Loss of Power

Custom Alarms 1 to 4

Programmed Alarm Messages

Water Under Floor

Smoke Detected
Standby GC Pump On

Loss of Water Flow

Standby Unit On

User Customized Alarm Messages

Available for Custom Alarms

Alarms Available

View Setpoints
Setup System

Run Diagnostics

Change Passwords

Setpoints/Setup

Normal Display

* Some alarms require optional equipment
** Optional

Setup Operation

Cold Start TD
Restart TD
IR Fill Rate
F/C Degrees
Min CW Temp**
CW/HW Flush**

Select Options

Heating
Humidifier
Dehumidifier
Heat Stages

Calibrate Sensors
Show DIP Switches (1-7)
Select Control Type

Intelligent
Proportional
Tunable PID

Proportional Gain
Derivative Gain
Integral Gain

Setup Alarms

Set Time Delays
Enable Alarms
Enable Common Alarm
Set Custom Alarm

Select Alarm
Change Custom TXT 1,2

Hum Control Method

Relative
Absolute

Analog Setup

A/D Input 1 (2,3,4)
Slope
Text
Intercept

Set Status Display
Calibrate Actuator

Setup System

Alarm History Log

Alarm 01 of 03
15-APR 09:20:45
High Humidity
Use / to Scroll

Run Diagnostics

Show Inputs

Test Outputs

Test Control Board

Analog Sensors

Analog in 1 (2,3,4):xx

AD #1 (2,3,4)
Use / to Scroll

ESCape to exit

No Alarms Present

OR

Alarm 01 of 01
High Head PR
Use / to Scroll