Periodic maintenance, Wire drive motor and gearbox, Gun and cable maintenance – Lincoln Electric SVM143-A User Manual

Page 39: Procedure for removing feedplate from wire feeder, Maintenance

Advertising
background image

D-3

MAINTENANCE

D-3

PERIODIC MAINTENANCE

Wire Drive Motor and Gearbox

Every year inspect the gearbox and coat the gear
teeth with a moly-disulfide filled grease. Do not use
graphite grease.

Every six months check the motor brushes. Replace
them if they are less than 1/4 in. long.

Gun and Cable Maintenance

See appropriate Operator’s Manual.

PROCEDURE FOR REMOVING
FEEDPLATE FROM WIRE FEEDER

1. Loosen the clamping collar screw using a 3/16 in.

Allen wrench. The clamping collar screw is
accessed from the bottom of the feedplate. It is
the screw which is perpendicular to the feeding
direction.

2. Loosen the retaining screw, which is also

accessed from bottom of feeder, using a 3/16 in.
Allen wrench. Continue to loosen the screw until
the feedplate can be easily pulled off of the wire
feeder.

DH-10

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC