F-10

TROUBLESHOOTING AND REPAIR

F-10

DH-10

Observe all Safety Guidelines detailed throughout this manual.

PROBLEMS
(SYMPTOMS)

POSSIBLE AREAS OF
MISADJUSTMENT(S)

RECOMMENDED
COURSE OF ACTION

The DH-10 is dead. The displays
and LEDs on the keypad are off
The green and red LEDs on the
control board are not lit.

The displays and LEDs on the key-
pad are off. The green and red
LEDs on the control board are both
blinking normally at about one sec-
ond intervals.

The displays and LEDs on the key-
pad are off. The green and/or red
LEDs on the control board are
blinking at a very fast or erratic
rate.

The wire feed is consistent and
adjustable, but operates at the
wrong speed.

1. Make sure the DH-10 is con-

nected properly to the power
source.

2. Make sure 42 VAC is being

applied to the DH-10 at the
input receptacle terminals A and
B.

1. Check the wires and connectors

(J11 and J3) between the dis-
play board and the control
board for loose or faulty connec-
tions.

1. Make sure the DH-10 is con-

nected properly to the power
source.

2. Make sure 42 VAC is being

applied to the DH-10 at the
input receptacle terminals A and
B.

1. Make certain the DIP switch S1

is correctly set for the wire drive
and gear ratio. See

Wire Drive

Head Selection.

1. The input rectifier bridge may

be faulty. Check for 42 VAC at
the red leads. Also check for at
least 42 VDC at leads #542(+)
to #500(-). See the Wiring
Diagram.

2. The control board may be

faulty.

1. Check leads #512 (1J3) to #500

(3J3) for the presence of
12.8 VDC. If the 12.8 VDC is
not present the control board
may be faulty.

2. If the 12.8 VDC is present the

display board may be faulty.

1. The control board may be

defective.

1. The control board may be

faulty.

FUNCTION PROBLEMS (Continued)

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric
Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

-----------------------------------------------------------------------------------------------------------------------------

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Advertising