background image

b-8

OPERATION

b-8

POWER FEED™ 10M DUAL WIRE FEEDER

USER DEFINED PARAMETERS

Parameter

Definition

Exit Setup Menu

P.0

This setup menu parameter can be used to exit the setup menu. When P.0 is displayed, press
the left Mode Select button to exit the setup menu.

P.1

Wire Feed Speed Units

This option selects which units to use for displaying wire feed speed.
English = inches/minute wire feed speed units (default).
Metric = meters/minute wire feed speed units.

P.2

Arc Display Mode

This option selects what value will be shown on the upper left display while welding.
Amps = The left display shows Amperage while welding (default).
WFS = The left display shows Wire Feed Speed while welding.

P.3

Display Options

This setup parameter was previously named "Display Energy"

If the previous software revision had this parameter set to display energy, that selection will
remain.

This option selects the information displayed on the alphanumeric displayes while welding. Not
all P.3 selections will be available on all machines. In order for each selection to be included in
the list, the power source must support that feature. A software update of the power source may
be needed to include the features.

Standard Display = The lower displays will continue to show preset information during and after
a weld (default).
Show Energy = Energy is displayed, along with time in HH:MM:SS format.
Show Weld Score = The accumulative weld score result is shown.

P.4

Recall Memory with Trigger

This option allows a memory to be recalled by quickly pulling and releasing the gun trigger. To
recall a memory, quickly pull and release the trigger the number of times that correspond to the
memory number. For example, to recall memory 3, quickly pull and release the trigger 3 times.
To recall memory 1, quickly pull and release the trigger the number of user memories plus 1.
Memories cannot be recalled while the system is welding.
Disabled = The gun trigger cannot be used to recall user memories (default).
Enabled = The gun trigger can be used to recall user memories.