Operation – Lincoln Electric POWER FEED IM916 User Manual

Page 31

Advertising
background image

b-13

OPERATION

b-13

POWER FEED™ 10M DUAL WIRE FEEDER

Parameter

Definition

P.501

Encoder Lockout

Locks one or both of the upper knobs (encoders), preventing the operator from changing wire feed speed,
amps, volts or trim. The function of each upper knob depends on the selected weld mode. When a costant
current weld mode is selected (e.g. Stick, TIG, Gouge), the upper right knob will always function as an
on/off switch. This parameter can only be accessed using Power Wave Manager software.

P.502

Memory Change Lockout

Determines if the memories can be overwritten with new contents.
No = Memories can be saved and limits can be configured (default).
Yes = Memories cannot be changed - saving is prohibited and limits cannot be re-configured.
This parameter can only be accessed using Power Wave Manager software.

P.503

Memory button Disable

Disables the specified memory button(s). When a memory is disabled, welding procedures cannot be
restored from or saved to that memory. If an attempt is made to save or restore a disabled memory, a
message will be displayed on the lower display indicating the memory number is disabled. In multi-head
systems, this parameter disables the same memory buttons on both feed heads. This parameter can only
be accessed using Power Wave Manager software.

P.504

Mode Select Panel Lock

Selects between several Mode Select Panel lockout preferences. When a Mode Select Panel selection is
locked and an attempt is made to change that parameter, a message will be displayed on the lower dis-
play indicating the parameter is locked.
All MSP Options Unlocked = All adjustable parameters on the Mode Select Panel are unlocked.
All MSP Options Locked = All knobs and buttons on the Mode Select Panel are locked.
Start & End Options Locked = The Start and End parameters on the Mode Select Panel are locked, all
others are unlocked.
Weld Mode Option Locked = The weld mode cannot be changed from the Mode Select Panel, all others
Mode Select Panel settings are unlocked.
Wave Control Options Locked = The Wave Control parameters on the Mode Select Panel are locked, all
others are unlocked.
Start, End, Wave Options Locked = The Start, End and Wave Control parameters on the Mode Select
Panel are locked, all others are unlocked.
Start, End, Mode Options Locked = The Start, End and Weld Mode Select parameters on the Mode Select
Panel are locked, all others are unlocked.
This parameter can only be accessed using Power Wave Manager software.

P.505

Setup Menu Lock

Determines if the setup parameters can be modified by the operator without entering a pass-
code.
No = The operator can change any set menu parameter without first entering the passcode
even if the passcode is non-zero (default).
Yes = The operator must enter the passcode (if the passcode is non-zero) in order to change
any setup menu parameters.
This parameter can only be accessed using Power Wave Manager software.

USER DEFINED PARAMETERS

Advertising