Installation – Lincoln Electric POWER FEED IM916 User Manual
Page 9
POWER FEED™ 10M DUAL WIRE FEEDER
A-1
INSTALLATION
A-1
TECHNICAL SPECIFICATIONS – Power Feed™ 10M Dual Wire Feeder
WIRE DRIVE OR WIRE DRIVE SECTION OF FEEDER
SPEC.#
TYPE
LOW SPEED RATIO
HIGH SPEED RATIO
∆ Dimensions do not include wire reel.
Wire Size
Wire Size
Speed
Solid
Cored
Speed
Solid
Cored
K2234-3 Bench Model
50-800 IPM
.025 - 3/32 in.
.035 - .125 in
75 - 1200 IPM
.025 - 1/16 in.
.035 - 5/64 in.
K2316-1 Boom Model
(1.27-20.3 m/m)
(0.6 - 2.4 mm)
(0.9 - 3.2 mm)
(2.0 - 30 m/m)
(0.6 - 1.6 mm)
(0.9 - 2.0 mm)
CONTROL bOx, WIRE DRIVE AND COMPLETE UNITS
SPEC.#
TYPE
INPUT POWER
PHYSICAL SIzE•
TEMPERATURE RATING
Dimensions
Height
Width
Depth
Weight Operating
Storage
K2234-3 Wire Drive &
19.9“
19.9“
30.6“
90 Lbs 14°F to 140°F -40°F to 185°F
Bench
Reel Stand
( 506 mm)
(506 mm)
(777 mm)
(40.8 Kg.) (-10°C to 40°C) (-40°C to 40°C)
Model
Feeder
WELDING CAPACITY RATING
Amp Rating
Duty Cycle
600 A
60%
500 A
100%