Telephone access interface – Lindy iSWITCH User Manual

Page 45

Advertising
background image

45

Telephone Access Interface



1. Dial up the iSwitch.
2. After three rings the iSwitch will respond by sending out three short beeps to the caller. Then the iSwitch

waits for the user to enter the password.

3. The user enters an access password (default password is 123456789#).
4. The iSwitch will send out three short beeps to confirm a successful login, or one long beep to deny access.
5. Once logged in, the remote user can punch in 4-8 digits. The first two digits specify which iSwitch, the next

digit specifies which output receptacle and the next digit specifies which command. The last four digits
specify the amount of time:
Command format: XXNA#:
XX - 00—16 is the iSwitch’s device number for a daisy chain, if there is no daisy chain, then any number is

accepted.

N - outlet number: 1(A)—8(H), 9 controls all the outlets.
A - action type: 0=off, 1=on, 2=reset.
I.E. 0111# RPM01 turn on Outlet A.
I.E. 0120# RPM01 turn off Outlet B.

I.E. 0212# RPM02 reset outlet A.

I.E. 01113600# means turn A on after 3600 minutes.
I.E. 01103600# means turn A off after 3600 minutes.
I.E. 01123600# means reset A after 3600 minutes.

6. Use a combination of 0111XXXX# or 0112XXXX# to get a different delay time. XXXX max value is 9999,

which is about 166 hours or 6.94 days.

7. Use the "*" key to cancel a command at any time.
8. The iSwitch will acknowledge the receipt of the commands by issuing 2 short beeps. A long beep indicates

a failure or a non-recognizable command.

9. To change the password. The default password is 123456789#. The user has to enter the previous

password in order to change their password.

NOTE: The Password has to have a minimum of 7 digits and can have a maximum
of 10 digits.

10. The user enters 888# or whatever previous password. Then the iSwitch responds with three short beeps

acknowledging access granted. The user then enters the new password as follows: 888XXXXXXXXXX#,
and the iSwitch acknowledges with 2 short beeps. Then user inputs 888XXXXXXXXXX# the second time to
re-confirm the new password. The iSwitch acknowledges with 4 short beeps, indicating that the password
has been changed.

11.

Hang up to close any access.

12. Forgot telephone interface password? Please do the following steps to restore the default password.

a. Dial up the iSwitch.
b. After three sequence rings, the iSWITCH will respond by sending out 3 short beeps to the caller and

waiting for user to enter password. Then pressing the button A and H simultaneously on the iSwitch
within twenty seconds.

c. When the LED A and H blinking, release the two buttons, the iSWITCH will respond by sending out 4

short beeps to the caller. The password will be restored to default.

13. The iSwitch is in a waiting loop to receive the command string. Each command string should be entered

within 20 seconds. After 180 seconds without any user input, the iSwitch will logout the user.

14. The 9 command set is for the administrator:

0190# to turn every port off.
0191# to turn every port on.
0192# to reset every port with a delay of 8 minutes, which will allow safe shutdowns. The delay can be

changed by command 888911XXXX#, where XXXX can range from 1 to 9999 minutes.

15. The user enters 000# that can force to break connection with iSwitch.

Advertising