Mar97 – Lincoln Electric INVERTEC IM526-B User Manual

Page 33

Advertising
background image

33

2

1

2

RECTIFIER

9D

C2

R7

9A

9A

N.F.

CONTROL PANEL

J11, J14

S

F

9

H5

402, 404

ON

OFF

H1

R

V

C

H6

12B

BOTTOM

51

WIRING DIAGRAM V300-PRO CODE 10257 (575V)

SHUNT

R8

250

L3

L1

C1

TP2

9D

S1

1, 8

POWER

J12

401, 403

12B

12B

25

J13

G

25W

R = RED

R4

W = WHITE

1

3

2

1

J11

J9

4
5

2
6

3

F

D13

317

6

9A

J16

5

14

315

316

51

LAYOUT

504

4

H3

6

J5, J16

32

32

227

213

214

INSIDE

S

TOP

+

S

TOP

5

2

W

303

3

8

J6

1

18V

285

AUX

TOP

OUTSIDE

S

BOTTOM

F

226

S

F

4

F

S

TRANSFORMER

MAIN

L2

CHOKE

F

S

53

4

1

5

2

3

6

52

53

53

14

REMOTE

214

SWITCH

POLARITY

WELDING

WIRE FEEDER

S6

42A

+

5

W

501

R

7

317

316

9D

6

314

R

W

POWER

R

BOARD

8

5

8

402, 404

307

+

T2

+

CURRENT

J2

M

J2, J8

S4

OUTPUT TERMINAL

SWITCH

25W

CV FCAW

+

25

+

Y

10K

Y

R5

9B

N.F.

912

2W

10K

R1

2

REMOTE

275A

LOCAL

2W

275B

207

77A

275C

276

150 5W

204B

228

212C

208

203

76

77B

204C

204A

220

229

R1

1

285

MODE SWITCH

S2

/INDUCTANCE

LOCAL/REMOTE

N

SPARE

GND

218

B

GND

275C

227

226

275B

CONTROL

4

77A

75

218

276

208

207

228

229

275D

301

305

4

D3

S

1

12

(V300-I ONLY)

210

211B

1

J1, J7

J9, J10, J12

J13, J15

6

J3

302

J7

4

309

224

TOP

AUX

H1

42

W

B

N.A.

H5

H1

2

H3

75

MIN

G

75

76

24V

F

76

E

77

31

212C

CR1

+ ARC

400A

C6

RIGHT

C9

BOARD

S

W

R

215

4

5

203

310

S5

503A

1

229

1

4

J14

3

2

CW (MAX)

215

CW (MAX)

306

212A

212B

J5

223B

7

12

210

13

J1

275A

2

309

J4

J6

COLOR CODE:

B = BLACK

1. FOR MACHINES SUPPLIED WITH INPUT CABLE (V300-PRO)

Y = YELLOW

FOR SINGLE PHASE INPUT: CONNECT GREEN LEAD TO GROUND PER NATIONAL ELECTRIC CODE.

CONNECT BLACK & WHITE LEADS TO SUPPLY CIRCUIT.

WRAP RED LEAD WITH TAPE TO PROVIDE 600V. INSULATION.

FOR THREE PHASE INPUT: CONNECT GREEN LEAD TO GROUND PER NATIONAL ELECTRIC CODE.

CONNECT BLACK, RED & WHITE LEADS TO SUPPLY CIRCUIT.

2. FOR MACHINES NOT SUPPLIED WITH INPUT CABLE (V300-I)

FOR SINGLE PHASE INPUT: GROUND MACHINE PER NATIONAL AND LOCAL ELECTRICAL CODES.

LEFT

CONNECT TERMINALS U & W TO SUPPLY CIRCUIT.

FOR THREE PHASE INPUT: GROUND MACHINE PER NATIONAL AND LOCAL ELECTRICAL CODES.

25

25W

42A

2AMP

H1

6AMP

212

212212

I

C

D

H

42

81

42

VAC

S2

MODE

SWITCH

R11

OUTPUT

CONTROL

S3

R12

S4

SWITCH

SWITCH

CONTROL

TERMINAL

THERMAL

OVERLOAD

INDICATOR

SWITCH

FUNCTION

METER

REMOTE

3

503

313

6

H6

H5

0V

FAN

212D

2

THERMOSTAT

A

V

310

D1B

5

6

8

F

4

301

8

2

4

223A

303

304

304

213

G = GREEN

2

FEEDER

NOTES:

N.A.

3

2

LOCAL/REMOTE

R11

F

501

2

2

3

4

PROTECTION

R1

B

+

912

25W

R9

D2

D1A

C15

L10191

CONTROL

ARC FORCE/INDUCTANCE

R12

SWITCH

METER FUNCTION

(V300-I ONLY)

INDICATOR

OVERLOAD

THERMAL

OUTPUT CONTROL

N.F. C1, C2, C14, C15 CAPACITORS ARE A MATCHED SET.

N.C. WIRE FEEDERS REQUIRING 24VAC, USE PINS "N" & "I".

COMPONENTS OR CIRCUITRY HAVING A COMMON CODE NUMBER.

THE INTERCHANGEABILITY OF A COMPLETE BOARD, THIS DIAGRAM MAY NOT SHOW THE EXACT

N.B. SINCE COMPONENTS OR CIRCUITRY OF A PRINTED CIRCUIT BOARD MAY CHANGE WITHOUT

AFFECTING

CONNECT TERMINALS U, V & W TO SUPPLY CIRCUIT.

212D

212B

211B

211A

8

302

275D

CV GMAW

5

3

502

4

12

11

211A

2

3

9

6

6

Y

14

8

4

7

11

Y

10

5

Y

503

9

503A

2

1

TP6

3

3

C5

4

204C

L4

42V

32A

110V

25W

313

311

306

275F

4

4, 5

25W

BOARD

13,15

13

C14

(LEFT)

401, 403

DRIVER

BOARD

1

9D

L5

N.C.

L

82

230V

4

220-

TRIGGER

5

4,5

I

10K

ON

223A

502

FAN

S3

MOTOR

SWITCH

CB2

J

575V

32A

A

CB1

212A

52

14

J15

51

J8

H5

1

1

INPUT

314

2

3

12A

7

R

8

12

13

14

229

SWITCH

BOARD

A

F -

H3

OUTPUT

OUTPUT

ARC FORCE

3

2

1

220

204B

204A

F

1

INSIDE

1, 8

286

CHOKE

1

BOARD

305

5

308

-

1

CC SOFT

BOTTOM

S

206

-

J10

ELECTRICAL SYMBOLS PER E1537

(VIEWED FROM COMPONENT SIDE OF BOARD)

CONNECTOR CAVITY NUMBERING SEQUENCE

311

RECEPTACLE

TRANSFORMER

CONTROL

AUXILIARY

T1

REMOTE

WIRE

-

21

4

3

52

25

10K

TP1

TP3

212

VAC

21

223B

PANEL

3

METER

4

5

6

5

- ARC

6

TP4

THERMOSTAT

W

J4

2

7

275F

7

504

1

CONTROL

1

3

9

10

224

PER

CC GTAW

CC CRISP

52

315

INPUT

TRANSFORMER

I

F

BOTTOM

9

206

U

OUTSIDE

W

D +

308

307

229

S5

TP5

K

41

H1

77B

(RIGHT)

T3

110/115

13,15

15

1

W

R

12

SWITCH

R6

25W

1

J3

10

B

NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diag

ram for a particular code is pasted inside

the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. G

ive the equipment code number..

MAR97

Advertising