HOLD − Using Temperature Hold Modes

When HOLD is displayed at the HOME screen, the ther-
mostat is in a temperature hold condition. This means that
the temperature program data is ignored and the thermo-
stat functions much like a non−programmable thermostat.

Adjusting Temperature Setpoint in Hold Mode

The temperature setpoint represents the desired tempera-
ture of the space around the thermostat. The default heat
setpoint in hold mode is 70°F; the default cool setpoint in
hold mode is 78°F.

To adjust the setpoint, press the UP or DOWN (

YB) arrow

buttons (see figure 8); the existing setpoint is displayed to
the right of the actual room temperature. Each button
press adjusts the setpoint up or down by 1 degree.

Heat

Prog

Fan

Settings

Cool

Day/Time

Hold

Enter

Hold Temperature Mode

Figure 8

(DOOR
OPEN)

Auto

Copy

(Outside)

70

i0:30

80

78

After the desired setpoint is reached, the HOME screen
will reappear after about 15 seconds.

Permanent Hold Mode

At any time the program is running, from the HOME
screen, set a permanent hold (program override) by press-
ing the HOLD button (see figure 8). The thermostat now
functions much like a non−programmable thermostat. Use
the Up/Down arrow buttons to adjust the hold setpoint. To
return to the program, press HOLD again.

Temporary (2-Hour) Hold

At any time the program is running, from the HOME
screen, set a temporary 2-hour hold by pressing the Up/
Down arrow buttons until the desired setpoint is displayed;

HOLD" flashes (see figure 9). This overrides the program

for 2 hours from the last button press, then returns to the
program.

While in Temporary Hold, press HOLD once to switch to
Permanent Hold (HOLD displays solid; PROG not dis-
played); press HOLD again to return to the program
(PROG displays; HOLD not displayed).

Heat

Prog

Fan

Settings

Cool

Day/Time

Hold

Enter

Temporary Hold Temperature Mode

Figure 9

(DOOR
OPEN)

Auto

Copy

(Outside)

68

i0:30

72

70

PROG − Thermostat Programming

The 51M38 thermostat can be programmed to perform a
set of both heating and cooling events for each day of the
week. Each day can be programmed for 4 unique events
per day, and each day can be different from any other day.

To Set Program Events and Temperatures

Figure 10 gives an example of how up to 7 different pro-
grams can be set. Programs A and C reflect the desired
warmth while the home IS occupied (72°); B allows less
heating while the home is NOT occupied; D reflects a cool
sleeping temperature.
NOTE − The example in figure 10 shows heat setpoints; a
similar program may be set for cool setpoints.

Figure 10

Program Example

6AM

NOON

6PM

MID

6AM

NIGHT

A

B

D

A

B

D

A

B

D

A

B

D

A

B

C

D

A

B

C

D

A

B

C

D

C

C

C

C

SATURDAY PROGRAM: 72°

68°

64°

SUNDAY PROGRAM: 72°

68°

64°

FRIDAY PROGRAM: 72°

68°

64°

THURSDAY PROGRAM: 72°

68°

64°

WEDNESDAY PROGRAM: 72°

68°

64°

TUESDAY PROGRAM: 72°

68°

64°

MONDAY PROGRAM: 72°

68°

64°

NOTE − Pressing the ENTER button during the following
programming steps, saves and exits to the HOME screen.
To program events and temperatures, perform the follow-
ing steps.