And 3), Able 3, Caution – Lennox International Inc. 51M37 User Manual

Page 53

Advertising
background image

Page 7

51M38 SERIES 5/2

Table 3

Default Program Settings (Time & Temp.)

Programs

Time

Temp. − Heat

Temp. Cool

All days − A

6:00am

70

_F / 21°C

78

_F / 26°C

All days − B

8:00am

62

_F / 17°C

85

_F / 29°C

All days − C

6:00pm

70

_F / 21°C

78

_F / 26°C

All days − D

10:00pm 62

_F / 17°C

82

_F / 28°C

Thermostat Output Table

Table 4 depicts the 51M38 thermostat output states for var-
ious input conditions.

Table 4

Thermostat Outputs

Condition

W1

Y1

G

Gas Heat, Auto Fan

Heat Demand

X

Cool Demand

X

X

No Demand

Gas Heat, Continuous Fan

Heat Demand

X

X

Cool Demand

X

X

No Demand

X

Electric Heat, Auto Fan

Heat Demand

X

X

Cool Demand

X

X

No Demand

Electric Heat, Continuous Fan

Heat Demand

X

X

Cool Demand

X

X

No Demand

X

NOTE − X = output is activated with 24VAC.

Technical Specifications

Thermostat Type

Electronic programmable thermostat for 1-Stage
Heat/1-Stage Cool, gas or electric heat, non−heat pump,
non−power robbing applications.

Power Supply Range

18VAC − 30VAC (24VAC nominal), 60Hz

CAUTION

24VAC is present on the terminals of the thermostat
bracket. If removing the thermostat from the wall,
use caution and avoid touching any of the connec-
tor terminals on the wall bracket.

Also, when working with the thermostat dip
switches, use a non−conductive tool and take cau-
tion to avoid making any contact with the circuit
board, its imprinted circuitry and its connector
prongs.

Temperature Display

Display Scale: Fahrenheit or Celsius user selectable (via
DIP switch; see figure 17)
Display range: 35°F (2°C) to 99°F (37°C)
Display resolution: 1°F (1°C)
Display Accuracy: +/−1°F
If the Fahrenheit/Celsius display must be changed, use a
plastic, non−conductive tool to push the dip switch to the
right position (see figure 17).

F/C (Fahrenheit/Celsius) switch
shown in Celsius position

Figure 17

Changing Fahrenheit/Celsius Setting

1
2
3
4
5
6
7

PLUG IN (Use Care To Avoid Bending Prongs.)

Indoor Temperature Measurement Range

Measurement Scale: Fahrenheit
Measurement Range: 35°F to 99°F
Measurement Resolution: 0.5°F
Measurement Accuracy: +/−1°F
Field Offset: via DIP switches to +/−3°F
Sampling Method: temperature measurements sampled
every 15 seconds. Displayed temperature is the average
of the last four measurements.

Outdoor Temperature Measurement Range

Measurement Scale: Fahrenheit
Measurement Range: −22°F to 122°F
Measurement Resolution: 1°F
Measurement Accuracy: +/−2°F

Temperature Setpoint Range

Setting range: 50°F (10°C) to 90°F (32°C)
Setting resolution: 1°F (1°C)

Advertising