12

3: Monitoring the 4092A

Table 1

defines each status or alarm bit position.

Table 1: Status or alarm binary codes

Status or alarm
character
position

Bit position

Bit value and description

a or f

19

Not used

18

Not used

16 and 17

Remote control bits:

0:0 = Autoswitch/don’t care

0:1 = Channel A selected

1:0 = Channel B selected

1:1 = Not used

b or g

15 and 14

Front panel switch control bits:

0:0 = Autoswitch/don’t care

0:1 = Channel A selected

1:0 = Channel B selected

1:1 = Not used

13

0 = Channel A active input

1 = Channel B active input

12

1 = Cannot lock to input B

c or h

11

1 = Cannot lock to input A

10

1 = Autoswitch occurred

9

1 = Power supply 2 fault

8

1 = Power supply 1 fault

d or i

7

1 = output 8 failed

6

1 = output 7 failed

5

1 = output 6 failed

4

1 = output 5 failed

e or j

3

1 = output 4 failed

2

1 = output 3 failed

1

1 = output 2 failed

0

1 = output 1 failed