2 checking model number and software version – Lantronix TSC 4092A IRIG-B User Manual

Page 18

Advertising
background image

14

3: Monitoring the 4092A

3.2.2 Checking Model Number and Software Version

Both commands are case sensitive. You do not need to type a carriage return or line feed.

To check the TSC model number:

„

Type: I

The system returns I4092A-00\r\n, where the 00 is the hardware version.

To check the software version

„

Type: V

The system returns Vxx\r\n where xx is the software version.

Example: V00.

S

Status command

S02000,00000

4092A set to autoswitch with active input set to B. Input A latched fault cleared.

A

Make channel A active
command

ALARM10000

Alarm output shows change in status. 4092A set to A with active input set to A.

S

Status command

S10000,12000

4092A set to A with active input set to A. Current status should match last alarm
output (ALARM10000). No latched alarms. Changed status (remote control bit
changed from B to A and active input changed from B to A).

S

Status command

S10000,00000

4092A set to A with active input set to A. No latched alarms. Changed status bits
cleared upon status request.

C

Autoswitch command

ALARM00000

Alarm output shows change in status. 4092A set to autoswitch with active input set
to A.

S

Status command

S00000,10000

4092A set to autoswitch with active input set to A. Current status should match last
alarm output (ALARM10000). No latched alarms. Changed status (remote control
bit changed from A to autoswitch).

S

Status command

S00000,00000

4092A set to autoswitch with active input set to A. No latched alarms. Changed
status bit cleared upon status request.

Table 2: Example Telnet session (Continued)

Command sent

4092A response