Appendix a: specifications, A.3 electrical specifications, A specifications – Lantronix TSC 4092A IRIG-B User Manual

Page 29: Appendix a, specifications

Advertising
background image

4092A Operations and Maintenance Manual

25

Appendix A: Specifications

A.3 Electrical Specifications

Table 3

lists the electrical specifications for the 4092A.

Table 3: Electrical specifications

Item

Specification

Protection Class

Class I (Grounded Type)

Power Input Voltage

100–240 V ~ 50/60 Hz 0.5 A, power dissipation ~20 Watts

Note: Fluctuations not to exceed ± 10% of nominal supply voltage.

Power Inlet Type

IEC 60320 sheet C14

AC Power Supply Cord Set

18 AWG (0.75 mm

2

minimum)

DC Power Supply

The external wiring to this connector must be at a minimum 1.5 mm² (14 AWG)
with a 15 A fuse or circuit breaker. A 20 A circuit breaker may be used if the
external wiring is jacketed 14 AWG, with maximum length of 20 feet. An
internal fuse mounted on the power supply carrier board is included to protect
this input but is not field replaceable. Mating connector for the DC power
supply is a AMP 1-350344-0 and 2 sockets are required, AMP 350388-1.

Power Supply Part Numbers

AC: TSC 4501A

DC: TSC 4502A

Power Mains Fuse

AC: (2) - 250V~1A time lag 5 x 20 mm. Initial shipments will have one fuse.

DC: No customer-serviceable fuses.

Unmodulated Signal Input

„

Frequency: 1–200 kHz

„

Lo-Z Impedance: 50

Ω ±5 Ω

„

Hi-Z Impedance: 600

Ω ±10 Ω

„

Input level: > 1.5 V peak to peak into 50

Modulated Signal Input

„

Code Format: IRIG-B

„

Frequency: 1 kHz (IRIG-B)

„

Lo-Z Impedance: 50

Ω ±5 Ω

„

Hi-Z Impedance: 600

Ω ±10 Ω

„

Input level: > 2.8 V peak to peak into 50

Connectors

„

Input: 2 BNC

„

Output: 8 BNC

„

LAN: RJ-45

Gain

0 dB

Isolation

> 70 dB

Advertising