Cajun M770 ATM Switch Manager User’s Guide

55

LEC-LES assignment

The method by which a LEC is assigned to a LES.
Possible methods are:

By longest address match

By group LES address

By round robin

For more information, refer to LEC to LES assignment
on page 63.

LECS ATM Address

The ATM address advertised by the LECS.

LECS Discovery

Indicates the method used by the management LEC
to establish a direct configuration VCC to the LECS.

Length

The length of the ATM address, expressed as a
number of bits. The maximum length is 152 bits, as
ATM routing is done for only 19 byte addresses.

LES Activity Status

The activity status of the LES. Possible statuses are:

active - The LES has resilient or distributed
capability and is active.

standby - The LES has resilient capability and is
on standby.

LES Address

The ATM address of the LES.

LES ATM Address

The ATM address of the LES that the management
LEC has joined.

LES ELAN Name

The name of the ELAN.

LES ELAN Type

The type of ELAN. Possible types are:
• Ethernet

Token Ring

LES Name

The name of the LES. This must correspond to an
ELAN with the same name.

Field Name

Description

Advertising