206-4147

Installer Menu (Cont.)

Detailed Descriptions of Installer Menu Items

000 - INSTALLER SEQUENCE
Specifi es entry sequence to the Installer Menu.

0 = 9876

1 = 4321

2 = 1478

3 = 3698

001 - POWER MANAGE (Power Management)
Determines hours of no activity before automatic shutoff. The
Power Management function is for saving energy. If set to 0,
Power Manage is Off. Settings range from 0 ~ 7, with 1 ~ 7 rep-
resenting the hours that the unit will remain ON, unless there has
been activity from either the control panel or remote control.

002 - AC ON (AC Power Switchable)
If set to 1, this allows the STB to turn ON when AC power is ap-
plied. Pressing the ON button is not necessary. This is desirable
if the STB is plugged into a cable box or a power outlet controlled
by a wall switch. Use the Left/Right arrow keys to choose 0 or 1,
where 0 is the default (OFF), and 1 is ON.
Note: If set to 1 (ON), the STB does not respond to On/Off com-
mands from either the remote or the display control panel, and the
SLEEP TIMER is also nonfunctional.

003 - BAND/AFC (Band/Automatic Frequency Control)
There are four possible settings for this option:

0 = Broadcast

1 = CATV (default)

2 = HRC

3 = IRC

If some channels were not found by Auto Tuning (Channel
Search), select the appropriate Band setting here, and add the
channels using the Channel Edit option in the Channel Menu.

004 - STRT CHANNEL (Start Channel)
If active, this function allows you to determine the initial channel
number when the STB is turned ON. This feature is useful for an
in-house information channel, since the STB would always select
that channel when it is turned ON. Setting this to 255 causes the
last channel viewed when the STB was turned OFF, to be the
tuned to channel when the STB is turned ON again.
Note: For a digital Start Channel, always remember to set item
104 to the Minor Start Channel number.

255 = Last channel

1 ~ 125 = Major Ch. # 0 = Aux

126 Map to Channel 3.

127 Map to Channel 4.

005 - CHAN LOCK (Channel Lock)
Channel Lock is ideal if the system must always be on the same
channel. Changing channels with the Channel Up/Down or key-
pad numbers is impossible. Channel Lock is inactive if set to 0
(default).
Generally, this feature is used in connection with STRT CHAN-
NEL (Installer Menu item 004) where the Start Channel may, for
example, be set to 3 or 4. If the Start Channel is 3, then the STB
will remain locked on channel 3.

NOTE: For items 007, 008, and 009
For legacy reasons, the scale used is 0 – 63. The PTC software
will translate this to the 0 – 100 scale used by the STB.

To translate an STB volume level to the Installer Menu value, use
the following formula:

Installer Value = STB Value x 63

100

Enter only the whole number (disregard fractions).

007 - STRT VOLUME (Start Volume)
This function allows the Installer to determine the initial volume
level setting when the STB is turned ON. This feature is useful
for an in-house information channel, since the STB would always
select that volume level when it is turned ON. The range of values
is 0 - 63, 255. If 255 is selected, the current volume level will be
retained in memory when the STB is turned OFF; at turn ON, the
volume level will be automatically set at the previous or last level.

008 - MIN VOLUME (Minimum Volume)
This function determines the minimum volume level allowable
with the Volume (VOL) Up/Down control. In this way, for example,
someone cannot set the volume too low to hear. The value range
is from 0 to 63. Use the Left/Right arrow keys to change values.
The factory default is 0, which provides the full range of volume
control, if item 009 MAX VOLUME is also set to 63. It may be best
to set the same value on every STB.
Note: The minimum volume level cannot have a value setting
higher than the maximum volume level (described below).

009 - MAX VOLUME (Maximum Volume)
This function determines the maximum volume level allowable
with the Volume (VOL) Up/Down control. In this way, for example,
someone cannot set the volume level high enough to disturb oth-
ers. The value range is 0 to 63, with 63 as the default, which gives
the user the full range of volume control, if item 008 MIN VOLUME
is also set at 0. Use the Left/Right arrow keys to change values. It
may be best to set the same value on every STB.
Note: The maximum volume level cannot have a value setting
lower than the minimum volume level (described above).

010 - MUTE DISABLE
Enables or disables sound mute function. If set to 1, sound cannot
be muted. If set to 0, sound can be muted.

015 - SLEEP TIMER
If set to 1, the Sleep Timer feature may be used. If set to 0, the
Sleep Timer is not available.

Advertising