Troubleshooting

5

BB-HCE481 Indicator Display Troubleshooting

Problem

Cause and Remedy

The indicator
lights or blinks
orange.

• The Ethernet cable is partly disconnected.

→ Change it to another Ethernet cable.

The indicator
continues
blinking orange.

• The camera is turned off when updating firmware.

→ If you access the camera using a web browser, The

Update Firmware page will be displayed. Update the
firmware following the procedure (see page 164 of the
Operating Instructions on the CD-ROM). If you fail to
update the firmware, see page 26.

The indicator
continues
blinking orange
(2-second
interval).

• An error has occurred in UPnP™ port forwarding.

→ Set up the camera again in [Automatic Setup] using the

Setup Program following the instructions in Getting
Started.

The indicator
continues
blinking green.

• Automatic setup is not complete.

→ Complete the setup following the instructions in Getting

Started.

• The camera did not receive an IP address from the DHCP

server.

→ When setting [Automatic Setup] or [DHCP Setup], the

camera may not be assigned an IP address due to network
failures. Ask your ISP or network administrator for more
information.