67 – user menu, Tape protect, Time code – Panasonic AJ-D850P User Manual

Page 67

Advertising
background image

– 67 –

USER menu

<TAPE PROTECT>

Item

Setting

No.

Superimposed

No.

Superimposed

Description

display

display

400

STILL

0000

0.5s

TIMER

0001

5s

0002

10s

0003

20s

0004

30s

0005

40s

0006

50s

0007

1min

0008

2min

401

SRC

0000

STEP

PROTECT

0001

HALF

402

DRUM

0000

OFF

STDBY

0001

ON

403

STOP

0000

STEP

PROTECT

0001

HALF

The underline on the setting item denotes the initial setting.

<Note>
In order to protect the tape and VTR helical heads, it is recommended that the Still Timer be
set for automatic tape protection mode in 30 seconds or under.

This selects the time to be taken until the unit goes into the
tape protection mode when it is left standing in the stop or
search still (JOG/VAR/SHTL) mode. (Unit: s = second, min =
minute)
<Note>
With the DV or DVCAM format, the maximum time which can
be set is 10 s even when a setting above 10 s has been
selected. The selection screen, however, will operate for up to
2 minutes.

This selects the operation during the tape protection mode
when the unit is left standing in the still status during the
search mode (JOG/VAR/SHTL).
0: STEP FWD.
1: HALF LOADING.
<Note>
When STEP FWD is selected, the unit automatically goes into
the HALF LOADING mode when the total time for which the
unit is left standing in the still status reaches 30 minutes
(DVCPRO) or 1 minute (DV or DVCAM).

This selects the drum operation in the STANDBY OFF mode.
0: The drum stops rotating.
1: The drum continues rotating.

This selects the operation in the tape protection mode when
the unit has been left standing in the STOP mode.
0: STEP FWD
1: HALF LOADING
<Note>
When STEP FWD is selected, the unit is automatically
transferred to the HALF LOADING mode when the total time
during which it has been left standing in the STOP mode
reaches 30 minutes (or 1 minute with a DV/DVCAM tape).

<TIME CODE>

Item

Setting

No.

Superimposed

No.

Superimposed

Description

display

display

500

VITC

0000

10L

POS-1

0001

11L

0002

12L

0003

13L

0004

14L

0005

15L

0006

16L

0007

17L

0008

18L

0009

19L

0010

20L

The underline on the setting item denotes the initial setting.

This sets the position where the VITC signal is to be inserted.
(The same line as for VITC POS-2 in 501 cannot be selected.)