SERVO CONTROL
ERROR

Counter display

Description

VTR operation

(Restart condition)

REEL DIR UNMATCH

If the reel motor at the take-up side is running in the
reverse direction, the AUTO OFF lamp lights, and the
message display flashes.

STOP
(POWER OFF

ON)

REEL TENSION ERROR

SERVO COMM ERROR

SERVO ERROR

S-FF/REW TIMEOVER

S REEL ROTA TOO
FAST

T REEL ROTA TOO
FAST

T REEL TORQUE
ERROR

UNLOAD ERROR

S REEL TORQUE
ERROR

WINDUP ERROR

If an abnormal tension at the supply side is detected
in the reel mode, the AUTO OFF lamp lights, and the
message display flashes.

STOP
(POWER OFF

ON)

When the servo microcomputer does not follow the
instructions of the system control microcomputer
even when 10 seconds have elapsed, the AUTO OFF
lamp lights, and the message display flashes.

STOP
(POWER OFF

ON)

When there is no response from the servo micro-
computer for 1 or more seconds, the AUTO OFF
lamp lights, and the message display flashes.

STOP
(POWER OFF

ON)

When only the servo microcomputer was reset in an
instantaneous power failure, the AUTO OFF lamp
lights, and the message display flashes.

STOP
(POWER OFF

ON)

If the start/end processing operation is not completed,
the AUTO OFF lamp lights, and the message display
flashes.

STOP
(POWER OFF

ON)

If the supply reel motor should rotate at an ab-
normally fast rate, the AUTO OFF lamp lights, and
the message display flashes.

STOP
(POWER OFF

ON)

If an abnormal torque applied to the supply reel motor
is detected, the AUTO OFF lamp lights, and the
message display flashes.

STOP
(POWER OFF

ON)

If the take-up reel motor should rotate at an ab-
normally fast rate, the AUTO OFF lamp lights, and
the message display flashes.

STOP
(POWER OFF

ON)

If an abnormal torque applied to the take-up reel
motor is detected, the AUTO OFF lamp lights, and
the message display flashes.

STOP
(POWER OFF

ON)

If the tape has not been wound up during unloading,
the AUTO OFF lamp lights, and the message display
flashes.

STOP
(POWER OFF

ON)

If the tape was not wound up at less than the
standard speed (1

×

) when the total tape amount was

not detected or if abnormal tape slack or tension was
detected at speeds above 1

×

after the total tape

amount was detected, the AUTO OFF lamp lights,
and the message display flashes.

STOP
(POWER OFF

ON)

WINDUP REEL NOT
ROTA

If, after the cassette has been inserted, the tape take-
up reel has not wound up the tape at the standard
speed (1

×

) or faster while the total tape amount is not

detected and while the tape is traveling in the forward
or reverse direction, the AUTO OFF lamp lights, and
the message display flashes.

STOP
(POWER OFF

ON)

Monitor display

SERVO CONTROL
ERR

REEL DIR UNMATCH

REEL TENSION ERROR

SERVO COMM ERROR

SERVO ERROR

S-FF/REW TIMEOVER

S REEL TOO FAST

T REEL TOO FAST

T REEL TORQUE
ERR

UNLOAD ERROR

S REEL TORQUE
ERR

WINDUP ERROR

W-UP REEL NOT ROTA

Advertising