Rs-232c interface, Error code table – Panasonic AJ-D850P User Manual

Page 94

Advertising
background image

RS-232C interface

– 94 –

3) Return format [VTR

controller (PC)]

The following responses are made to the command. If necessary, more than one response is made.

When the communication has terminated normally

1. The receive completion message is returned.

[ACK]

06h

2. The execution completion message is returned.

[STX] [command] [data] [ETX]

02h

XX XX XX XX-XX 03h

• [command]: This is the message (data) which is returned or the execution completion message identifier.
• [data]:

This is the data to be returned. It can be omitted.

Example:

Send command

Return message (data)

[STX] OPL [ETX]

[ACK] [STX] OPL [ETX]

When the communication has terminated abnormally

[NACK]

15h

When processing is not possible due to incorrect data or trouble in the VTR

1. The receive completion message is returned.

[ACK]

06h

2. An error code is returned.

[STX] E R N

1

N

2

N

3

[ETX]

02h

Error code

03h

4. Error code table

ER001: Invalid command

• Unsupported command received.
• Error in command execution

ER002: Parameter error
ER102: VTR mode error (front loading motor)
ER103: VTR mode error (loading motor)
ER104: VTR mode error (drum, capstan system)
ER105: VTR mode error (reel system)
ER106: VTR mode error (tension system)
ER108: VTR dew error
ER1FF: VTR system error

Advertising