Cld-v2800 level iii • chapter two – Pioneer CLD-V2800 User Manual

Page 16

Advertising
background image

3) The Serial Interface

The Signal Level
The signal level for the RS-232C is

±

12v.

The Data type

Parity bit

: No parity.

Data length : 8 bits.
Stop bit

: 1 bit.

The Transmission speed
9600, 4800, 2400, or 1200 baud can be selected by using Dip Switches 1 and 2 on
the back of the player: The Factory default setting is 4800 BAUD.

NOTE: A BAUD rate of 4800 or 1200 can also be set by sending a Level III
command to Set Register C. See page 3-42 for details.

CLD-V2800 Level III • Chapter Two

2-4

TP 120

v. 1.0 • 10/95

CLD-V2800 Level III User’s Manual

0

1

START

STOP

D0

D1

D2

D3

D4

D5

D6

D7

1 START + 8 DATA + 1 STOP

Figure 2-E

BAUD

SW1

SW2

9600

UP

UP

4800

DOWN

UP

2400

UP

DOWN

1200

DOWN

DOWN