12 ip configuration – Planet Technology ISW-800M User Manual

Page 35

Advertising
background image

Power Alarm interface

4.12 IP Configuration

Power alarm function enables the Relay alarm action. Without enabling power alarm function, the Relay

alarm action will not work even the Relay alarm is set. Mark the check box and click

button.

DHCP Client:

Enable or Disable the DHCP client function. When DHCP client function is enabling,

the industrial switch will be assigned the IP address from the network DHCP server. The default IP

address will be replace by the DHCP server assigned IP address. After you click "Apply" button, a

popup dialog show up. It is to inform the user that when the DHCP client is enabling, the current IP

will lose and user should find the new IP on the DHCP server. To cancel the enabling DHCP client

function, click "cancel".

IP Address:

assign the IP address that your network is using. If DHCP client function is enabling,

and then you do not need to assign the IP address. And, the network DHCP server will assign the IP

address for the industrial switch and display in this column. The default IP is 192.168.10.1.

Subnet Mask:

assign the subnet mask of the IP address. If DHCP client function is enabling, and

then you do not need to assign the subnet mask.

Gateway:

assign the network gateway for the industrial switch. The default gateway is

192.168.10.254.