Front panel leds, Dsx-1-compatible unit, Led meaning – Paradyne 7924 User Manual

Page 35

Advertising
background image

Monitoring the Unit

6-6

7924-A2-GB20-30

October 1997

Front Panel LEDs

DSX-1-Compatible Unit

Upon power up, the first three LEDs blink in sequence, indicating a successful
start configuration. The green PWR LED lights whenever power is applied to the
board. Loop LEDs blink until the loop has been synchronized and then remain off.

TM

TERMINAL

T1 HDSL

Local Remote Loop Bk

PWR

FAIL

Loop A Loop B

NETWORK

SYSTEM

HDSL

TM

7900

7900

97-15312

LED

Meaning

Local

ON: The local T1 interface has a loss of signal.

Remote

ON: The remote T1 interface has a loss of signal.

Loop Bk

ON: A loopback has been initiated for testing the equipment connected to
this unit. Refer to Chapter 7,

Testing,

for more information.

PWR

ON: Power is applied to the unit.

FAIL

ON: The processor has halted and repairs are required.

Loop A

ON: HDSL Loop A has failed.

Blinking: HDSL Loop A is synchronizing with the far-end unit (such as
when the units are coming up after a reset). If the LED blinks for more
than 60 seconds, loss of signal has occurred.

Off: Loop A is enabled and synchronized.

Loop B

ON: HDSL Loop B has been disabled (only Loop A is in use) or has
failed.

Blinking: HDSL Loop B is synchronizing with the far-end unit (such as
when the units are coming up after a reset). If the LED blinks for more
than 60 seconds, loss of signal has occurred.

Off: Loop B is enabled and synchronized.

Advertising