Dsx-1-to-dsx-1 configuration – Paradyne 7924 User Manual

Page 43

Advertising
background image

Worksheets

A-2

7924-A2-GB20-30

October 1997

DSX-1-to-DSX-1 Configuration

Multiplexer

DSX-1 Unit

DSX-1

Multiplexer

DSX-1 Unit

DSX-1

Cross-campus

2- or 4-wire

facility

Customer Premises

Central Site

97-15296

To connect two DSX-1-compatible units, configure the units as follows. Terminal
mode factory defaults are in bold (for Switchpack mode defaults, see Appendix C,

Switchpacks and Jumpers

).

Configuration
Option

DSX-1-Compatible Unit
(Customer Premises)

DSX-1-Compatible Unit
(Central Site)

Card Type

CP (default)

CO

Loops Enabled

Dual (Loops A & B) or
Single (Loop A)

Must be same as CP side

T1 Line Encode

B8ZS or AMI

Must be same as CP side

Framing

D4, Extended Superframe,
or Unframed

Must be same as CP side

Line Build-Out

Enter 5 at the Config
command prompt. Select
from the following options:

1) 0 to 133 ft

2) 133 to 266 ft

3) 266 to 399 ft

4) 399 to 533 ft

5) 533 to 655 ft

Enter 5 at the Config command
prompt. Select from the following
options:

1) 0 to 133 ft

2) 133 to 266 ft

3) 266 to 399 ft

4) 399 to 533 ft

5) 533 to 655 ft