Dsx-1-to-v.35 configuration – Paradyne 7924 User Manual
Page 44
Worksheets
A-3
7924-A2-GB20-30
October 1997
DSX-1-to-V.35 Configuration
Router
V.35 Unit
V.35
LAN
Customer Premises
DSX-1
DSX-1
Central Site
Cross-campus
2- or 4-wire
facility
97-15420
Multiplexer
To connect a V.35-compatible unit on the CP side and a DSX-1-compatible unit
on the CO side, configure the units as follows. Terminal mode factory defaults are
in bold (for Switchpack mode defaults, see Appendix C,
Configuration
Option
V.35-Compatible Unit
(Customer Premises)
DSX-1-Compatible Unit
(Central Site)
Card Type
CP
CO
Loops Enabled
Dual (Loops A & B) or
Single (Loop A)
Must be same as CP side
Payload Rate
1 – 9 (64 – 1536 kbps)
Options 8 (1024 kbps) and 9
(1536 kbps) are only available
if both Loops A & B are
enabled.
N/A
Framing
N/A
Use D4, Extended Superframe, or
Unframed. See
on page A-4 before
selecting Unframed.
T1 Line Encode
N/A
B8ZS or AMI
Line Build-Out
N/A
Enter 5 at the Config command
prompt. Select from the following
options:
1) 0 to 133 ft
2) 133 to 266 ft
3) 266 to 399 ft
4) 399 to 533 ft
5) 533 to 655 ft