Monitoring the Unit

6-7

7924-A2-GB20-30

October 1997

V.35-Compatible Unit

The green PWR LED lights whenever power is applied to the board. Loop LEDs
blink until the loop has been synchronized and then remain off.

TERMINAL

T1 HDSL

DTR

DSR

Loop BkPWR

FAIL

Loop A Loop B

7900

CTS

RT

S

RXD

TXD

97-15313

LED

Meaning

Loop Bk

ON: A loopback has been initiated for testing the equipment connected to
this unit. Refer to Chapter 7,

Testing,

for more information.

PWR

ON: Power is applied to the unit.

FAIL

ON: The processor has halted and repairs are required.

Loop A

ON: HDSL Loop A has failed.

Blinking: HDSL Loop A is synchronizing with the far-end unit (such as
when the units are coming up after a reset). If the LED blinks for more
than 60 seconds, loss of signal has occurred.

Off: Loop A is enabled and synchronized.

Loop B

ON: HDSL Loop B has been disabled (only Loop A is in use) or has
failed.

Blinking: HDSL Loop B is synchronizing with the far-end unit (such as
when the units are coming up after a reset). If the LED blinks for more
than 60 seconds, loss of signal has occurred.

Off: Loop B is enabled and synchronized.