CONNECTING TO GAS SUPPLY

Continued

FUEL REQUIREMENTS:

Connect regulator/hose with standard 20-pound

LP cylinder coupler.

Call the LP gas supplier to inspect the cylinder.

Do not use a damaged LP gas cylinder.

Do not use LP gas without proper

decompression.

Do not connect irregular LP gas supply with

heater.

Use only LP gas on this heater. Do not convert to

other gases.

CAUTION: It is dangerous to use a damaged
or rusted cylinder.

OPERATING HEATER

This heater is designed for use with LP gas. You may
light the heater directly.
LP gas is heavier than air. If it leaks from joint, it may
sink down to the floor and mix with ambient air to form
a detonable mixture. If you have questions, contact
your LP dealer for instructions or service.

Warning: Fire, burn, inhalation and explosion
hazard. Keep solid combustibles, such as
building materials, paper or cardboard, at safe
clearances from the heater. Never use heater in
the vicinity of gasoline, solvent, paint thinner or
other combustibles.

Caution: When heater runs in the presence of
other people, the user is responsible to properly
offer those present safety precautions and
hazard information.

LIGHTING INSTRUCTIONS:

Follow adaptable lighting instructions. Apply soap
solution to all joints. Bubbles forming show a leak. Do
not use a match or an open flame to detect leak. Light
heater after ensuring that no gas leak exists.

START HEATER:

1. Turn the control valve knob clockwise to the “OFF”

position.

2. Turn the door knob clockwise and open the heater

door.

3. Check all connections as described in the

“Connecting to Gas” section of this manual on
page 5.

OPERATING HEATER

Continued

4. Fully open the valve on the propane cylinder.
5. Push in gas control knob and turn it to IGN/ON

position. Then Push and release the ignition button
repeatedly until there is a flame at the pilot.

6. Keep control knob pressed in for 30 seconds after

ignition, then release.

7. Turn the burner on to maximum rate and then set

to desired setting or remain on HI.

8. Replace heater compartment door.

TO TURN OFF HEATER:
1. Turn gas control knob to the “OFF” position.
2. If heater is not to be used, shut off cylinder valve.
3. Do not attempt to relight heater within 5 minutes

after the propane cylinder valve has been closed.

RESTART HEATER:
1. Turn gas control knob clockwise to “OFF” position.
2. Wait 5 minutes before restarting.
3. Repeat step 5,6,7.

MAINTENANCE AND STORAGE

1. The Lp-gas supply cylinder to be used must be

constructed and marked in accordance with the
specifications for LP-gas cylinder of the U.S.
Department of transportation.

2. Storage of an appliance indoors is permissible only

if the cylinder is disconnected and removed from
the appliance. Cylinders must be stored outdoors
in a wellventilated area out of the reach of children.
Disconnected cylinders must have threaded valve
plugs tightly installed and must not be stored in a
building, garage or any other enclosed area.

3. The pressure regulator and hose assembly

supplied with the appliance must be used and a
statement that replacement pressure regulators
and hose assemblies must be those specified by
the appliance manufacturer.

4. If the connection to the LP-gas cylinder is other

than Type I, II or III (as described in the Standard
for

Cylinder Connection Devices, ANSI

Z21.81/CGA 6.25), the cylinder with its mating
fitting shall be provided by the appliance
manufacturer. Supplying the cylinder may be
accomplished by a method controlled by the
manufacturer that will result in both the appliance
and the cylinder being available at the time of
purchase.

5. The cylinder supply system must be arranged for

vapor withdrawal.

6. The cylinder used must include a collar to protect

the cylinder valve.

7. Have the heater inspected by qualified service man

before each use or at least annually.

8. Check the POL fitting for any damage before each

use and replace if any damage is found.

9. Turn off cylinder valve when the heater is not to be

used.

Advertising