Error messages

(continued)

<Note>

Consult your dealer if the error message display persists even after the unit has been restarted.

Error messages (continued)

Monitor display

Description

Corrective action

VTR

operation

E-55
UNLOAD ERROR

If the tape has not been taken up during unloading, this error
number flashes on the display.

Set the POWER switch to OFF
and then to ON again.

STOP

E-57
S-FF/REW
TIMEOVER

If the start or end processing operation is not completed, this error
number flashes on the display.

Set the POWER switch to OFF
and then to ON again.

STOP

E-59
DRUM ROTA TOO
SLOW

If the cylinder motor speed is abnormally low, this error number
flashes on the display.

Set the POWER switch to OFF
and then to ON again.

STOP

E-60
DRUM ROTA TOO
FAST

If the cylinder motor speed is abnormally high, this error number
flashes on the display.

Set the POWER switch to OFF
and then to ON again.

STOP

E-61
CAP ROTA TOO
SLOW

If the capstan motor speed is abnormally low, the error number
flashes on the display.

Set the POWER switch to OFF
and then to ON again.

STOP

E-64
S REEL ROTA TOO
FAST

If the supply reel motor speed is abnormally high, the error number
flashes on the display.

Set the POWER switch to OFF
and then to ON again.

STOP

E-67
T REEL ROTA TOO
FAST

If the take-up reel motor speed is abnormally high, the error number
flashes on the display.

Set the POWER switch to OFF
and then to ON again.

STOP

E-69
T REEL TORQUE
ERR

If excess torque being applied to the take-up reel motor is detected,
the error number flashes on the display.

Set the POWER switch to OFF
and then to ON again.

STOP

E-70
S REEL TORQUE
ERR

If excess torque being applied to the supply reel motor is detected or
an abnormal current flowing to the current detection resistor is
detected, this error number flashes on the display.

Set the POWER switch to OFF
and then to ON again.

STOP

E-71
CAP TENSION
ERROR

If abnormal tension at the supply side is detected in the capstan
mode, the error number flashes on the display.

Set the POWER switch to OFF
and then to ON again.

STOP

E-72
REEL TENSION
ERROR

If abnormal tension at the supply side is detected in the reel mode,
the error number flashes on the display.

Set the POWER switch to OFF
and then to ON again.

STOP

E-73
REEL DIR
UNMATCH

If the take-up reel motor has rotated in the reverse direction, this
error number flashes on the display.

Set the POWER switch to OFF
and then to ON again.

STOP

E-74
DRUM TORQUE
ERROR

If excess torque being applied to the cylinder motor is detected, this
error number flashes on the display.

Set the POWER switch to OFF
and then to ON again.

STOP

E-78
M-IF COMM ERROR

If a problem has been encountered in communication between the
servo microcomputer and mechanism relay board, this error number
flashes on the display.

Set the POWER switch to OFF
and then to ON again.

STOP

E-bA
BATTERY

This appears when the input DC voltage has dropped below the
undercut voltage.

Check the output voltage of the
equipment supplying DC
power.

STOP

Advertising