5 angle measurement, 1 measuring an angle – Pentax R-315(N) User Manual

Page 38

Advertising
background image

5 ANGLE MEASUREMENT

5-1 Measuring an Angle

Aim at the first target, then press [F3] [0 SET]
twice in succession to reset the horizontal
angle to 0.

Aim at the second target, then read the
horizontal angle.

Pressing [F4] [DISP] displays the vertical
angle.

The [0 SET] key cannot reset the vertical angle to 0.

Pressing the [DISP] key cycles through the sets of display items:
“H.angle/H.dst./V. dst.”, “H angle/V.angle/S.dst.”, and “H.angle/V.
angle/H.dst./S.dst./V.dst.”.

Even though you turn the power off during a survey, the horizontal angle
displayed last time is saved, so that it is restored when the power is turned on
next time.

When the restored horizontal angle is not necessary, reset it to 0.

36

5 ANGLE MEASUREMENT

MODE A

15

°

C

S0

H

. angle

0 0 "

0 0 '

0

°

H

. dst.

V

. dst.

MEAS TARGET 0 SET

DISP

MODE

MODE A

15

°

C

S0

H

. angle

2 0 "

3 0 '

6 0

°

H

. dst.

V

. dst.

MEAS TARGET 0 SET

DISP

MODE

MODE A

15

°

C

S0

H

. angle

2 0 "

3 0 '

6 0

°

V

. angle

4 0 "

0 5 '

8 7

°

S

. dst.

MEAS TARGET 0 SET

DISP

MODE

PENTAX R-300 (p20-52) 10/30/02 11:08 AM Page 36

Advertising
This manual is related to the following products: