10-7 Optical Plummet

Checks

q

Set the instrument on the tripod, and place a piece of white paper with a
cross drawn on it right under the instrument.

w

Look through the optical plummet, and move the paper so that the intersecting
point of the cross comes to the center of the field of view.

e

Adjust the leveling screws so that the center mark of the optical plummet
coincides with the intersecting point of the cross.

r

Rotate the instrument around the vertical axis. Look through the optical
plummet each 90° of rotation, and observe the center mark position against
the intersecting point of the cross.

t

If the center mark always coincides with the intersecting point, no adjustment
is necessary.

Adjustments

q

If the center mark does not coincide with the intersecting point, rotate the
optical plummet focusing knob cover and remove it.

w

Mark the point set on the line of sight at each step of 90° on the white paper
and call them A, B, C and D.

e

Join the opposed points (A,C and B,D) with a straight line, and set the
intersecting point 0.

r

Turn the four optical plummet adjusting screws with a adjusting pin so that the
center mark coincides with the intersecting point 0.

t

Repeat from

r

, and check that adjustment is correct.