10 CHECKS AND ADJUSTMENTS

10-4 Perpendicularity of Line of sight to horizontal axis

Checks

q

Position a target Point A at a distance 30m - 50m away from the instrument,
and sight it with the telescope.

w

Loosen the telescope lock screw and turn the telescope until a point is sighted
at a distance roughly equal to that of Point A. This is Point B.

e

With the telescope still reversed loosen the horizontal lock screw and rotate
the instrument around the vertical axis, and sight Point A again.

r

Loosen the telescope lock screw and turn the telescope until a point is sighted
at a distance equal to that of Point B. This is Point C.

t

No adjustment is necessary if Point B and C are aligned.

Adjustments

q

If Points B and C are not aligned, mark Point D at 1/4 the length of the BC,
from Point C in the direction of Point B.

w

Using the adjustment pin, rotate the reticle adjustment screws horizontally
opposite each other (see preceding page), and move the reticle to sight Point
D.

e

Repeat the check and make sure the adjustment is correct.

30 - 50m

30 - 50m

q

e

w

w

r

A

B

D
C

PENTAX R-300 (p65-88) 10/30/02 11:11 AM Page 69