COMPLAINT CAUSE

REMEDY

Fan motor noise.

Fan

If cracked, out of balance, or partially missing,
replace it.

Turbo

If cracked, out of balance, or partially missing,
replace it.

Loose set screw

Tighten it.

Worn bearings

If knocking sounds continue when running or
loose, replace the motor. If the motor hum or
noise appears to be internal while running,
replace motor.

Compressor will not run,

Voltage

Check voltage. See the limits on the preceding

fan motor runs.

page. If not within limits, call an electrician.

Wiring

Check the wire connections; if loose, repair or
replace the terminal. If the wires are discon-
nected, refer to wiring diagram for identification,
and replace the wires. Check the wire connections;
If not according to the wiring diagram, correct
the connections.

Thermistor

Check the TEMP control. If not at the lowest
number, set TEMP control to this setting and
restart the unit.

Check the continuity of the thermistor. Replace
the thermistor if the circuit is open.

Capacitor (discharge

Check the capacitor.

capacitor before

Replace if not within ±10% of manufacturer’s

servicing.)

rating, replace if shorted, open, or damaged.

Compressor

Check the compressor for open circuit or
ground. If open or grounded, replace the
compressor.

Overload

Check the compressor overload if externally mounted.
Replace if open. (If the compressor temperature is
high, remove the overload, cool, and retest.)

Compressor cycles on

Voltage

Check the voltage. See the limits on the

overload.

preceding page. If voltage is not within these limits,
call an electrician.

Overload

Check overload, if externally mounted.
Replace if open. (If the compressor temperature
is high, remove the overload, cool, and retest.)