Panasonic CW-XC244HU User Manual

Page 27

Advertising
background image

—27—

COMPLAINT CAUSE

REMEDY

Compressor cycles on

Fan motor

If not running, determine the cause. Replace if

overload. required.

Condenser air flow

Remove the cabinet, inspect the interior surface

restriction

of the condenser. If restricted, clean carefully
with a vacuum cleaner (do not damage fins) or
brush. Clean the interior base before
re-assembling.

Condenser fins

If the condenser fins are closed over a large

(damaged)

area on the coil surface, head pressures will
increase, causing the compressor to cycle.
Straighten the fins or replace the coil.

Capacitor

Test the capacitor.

Wiring

Check the terminals. If loose, repair or replace.

Refrigeration system

Check the system for a restriction.

Insufficient cooling

Air filter

If restricted, clean or replace.

Ventilation damper door

Close if open.

Unit undersized

Determine if the unit is properly sized for the
area to be cooled.

Excessive noise

Turbo fan

Check the set screw, or clamp. If loose or miss-
ing, correct. If the turbo or fan is hitting scroll
or barrier, rearrange the air handling parts.

Copper tubing

Remove the cabinet and carefully rearrange the
tubing not to contact the cabinet,
compressor, shroud, and barrier.

Auto air-swing fails.

Wiring

Check terminals. If loose, repair or replace.

Synchronous motor.

Check the synchronous motor for open circuit.

Advertising