(9-pin DRIVE Connector)

Name

In/Out

Description and Specifications

SHLD

Shield—Internally connected to chassis (earth) ground.

COM

Signal common for shutdown. Not connected to any ground or other COM.

SHTNC OUT

Shutdown relay output to drives that require a closed contact to disable the drive. The shutdown relay is active (disabling the
drive) when no power is applied to the OEM6250. When the OEM6250 is powered up, the shutdown relay remains active until
you issue the

DRIVE11

command. Max. rating: 175VDC, 0.25A, 3W.

Shutdown active (

DRIVE¯¯

): this output is internally connected to COM (see schematic above).

Shutdown inactive (

DRIVE11

): this output is disconnected from COM (see schematic above).

SHTNO OUT

Shutdown relay output to drives that require an open contact to disable the drive. The shutdown relay is active (disabling the
drive) when no power is applied to the OEM6250. When the OEM6250 is powered up, the shutdown relay remains active until
you issue the

DRIVE11

command. Max. rating: 175VDC, 0.25A, 3W.

Shutdown active (

DRIVE¯¯

): this output is disconnected from COM (see schematic above).

Shutdown inactive (

DRIVE11

): this output is internally connected to COM (see schematic above).

DFT

IN

Drive fault input. Set active level with the

DRFLVL

command. The drive fault input will not be recognized until you enable the

input functions with the

INFEN1

command. HCMOS compatible (Low

£

1.00V, High

³

3.25V) with internal 6.8 K

W

pull-up

resistor to internal +5VDC supply.

AGND

Analog ground.

RSVD

reserved

CMD–

IN

Command signal return.

CMD+ OUT

Command output signal.

±

10V analog output. 12-bit DAC. Load should be > 2K

W

impedance.

CONNECTIONS TO SPECIFIC DRIVES

APEX Series Drives

OEM6250

SHLD
COM
SHTNC
SHTNO
DFT
AGND
RSVD
CMD-
CMD+

DRIVE 1

APEX Series

Drive

Reset

Gnd

Vel Int Enable

Enable In

Fault Out

Gnd

Command+
CommandÐ

Tach Output

Gnd

+15V

Gnd

-15V

CHA+
CHAÐ
CHB+
CHBÐ
CHZ+
CHZÐ

Gnd

APEX Series Drive

Enable In

Fault Out

Gnd

Command+

Command–

CHA+

CHA–

CHB+

CHB–

CHZ+

CHZ–

Gnd

«
«
«
«
«
«
«
«
«
«
«
«

OEM6250

SHTNO

DFT

AGND

CMD+

CMD–

A–

A+

B+

B–

Z+

Z–

GND

NOTE:

Apex Series CHA+ connected to OEM6250’s A–
Apex Series CHA– connected to OEM6250’s A+

ENCODER 1