Encoder, Connections & internal schematics, Pin outs & specifications – Parker Hannifin SERVO CONTROLLER OEM6250 User Manual

Page 19

Advertising
background image

Chapter 1. Installation

1 3

Encoder

CONNECTIONS & INTERNAL SCHEMATICS

+5V
A+
A–
B+
B–
Z+
Z-
GND
SHLD

Internal Schematic

Chassis Ground

Digital Ground

ENCODER Connector

+5VDC

Incremental

Encoder

Max. Cable Length is 100 feet.
Use 22 AWG wire.

+5VDC

Red

A Channel +

Brown

A Channel –

Brown/White

B Channel +

Green

B Channel –

Green/White

Z Channel +

Orange

Z Channel –

Orange/White

Ground

Black

Shield

Shield

Wire colors for Compumotor E Series encoders

+1.8VDC

22 K

W

22 K

W

+5VDC

Same Circuit
as A Channel

+5V
A+
A–
B+
B–
Z+
Z-
GND
SHLD

+5VDC

Red

A Channel –

Yellow

A Channel +

White

B Channel +

Green

B Channel –

Blue

Z Channel +

Orange

Z Channel –

Brown

Ground

Black

Shield

Shield

Wire colors

Encoder Cable

SM Motor

ENCODER Connector

NOTE: Be sure to connect
the A– encoder lead (yellow)
to the A+ terminal, and
connect the A+ encoder lead
(white) to the A– terminal.

PIN OUTS & SPECIFICATIONS

(ENCODER Connector)

Pin Name

In/Out

Description

9

8

7

6

5

4

3

2

1

+5V

A+

A–

B+

B–

Z+

Z–

GND

SHLD

OUT

IN

IN

IN

IN

IN

IN

-----

-----

+5VDC output to power the encoder.

A+ Channel quadrature signal input.

A– Channel quadrature signal input.

B+ Channel quadrature signal input.

B– Channel quadrature signal input.

Z+ Channel signal input.

Z– Channel signal input.

Digital ground.

Shield—Internally connected to chassis ground (earth).

Specification for all encoder inputs

Differential comparator accepts two-phase quadrature
incremental encoders with differential (recommended) or
single-ended outputs. Max. frequency is 1.6 MHz. Minimum
time between transitions is 625 ns. TTL-compatible voltage
levels: Low

£

0.4V, High

³

2.4V. Maximum input voltage is

5VDC.

Requirements for Non-Compumotor Encoders

• Use incremental encoders with two-phase quadrature output. An index or

Z channel output is optional.

Differential outputs are recommended.

• It must be a 5V (< 200mA) encoder to use the OEM6250’s +5V output. Otherwise, it must be separately

powered with TTL-compatible (low

£

0.4V, high

³

2.4V) or open-collector outputs.

• If you are using a single-ended encoder, leave the A–, B– and Z– terminals on the OEM6250 unconnected.

Advertising