Jumpers & switches, Jumper setting (interface select), Serial interface switch – POSIFLEX Business Machines PP3000 User Manual

Page 28

Advertising
background image

U6&U8 : Font and BIOS socket

This socket is used to install BIOS and character font. Each type of printer
requires different BIOS and character font. For example, the BIOS for friction
type mechanism and the BIOS for sprocket type mechanism are different.

JUMPERS & SWITCHES

Jumper Setting (Interface Select)

INTERFACE

JP3 JP4

JP6-JP13 JP14

JP15

SERIAL PORT

OPEN

1-2 SHORT 1-2 SHORT SHORT

PARALLEL PORT 2-3 SHORT 2-3 SHORT 2-3 SHORT OPEN

When using either interface, the connector of the other interface must be

disconnected. DIP SW3 and DIP SW4 have to be turned off when parallel
interface is used.

Serial Interface Switch

DIP - SW1
Switch

Function

ON

OFF

1-1

Data transmission

1-2

Rate (baud rate )

See next table

1-3

1-4

Not used

1-5

Hand shake

DTR mode

X-ON/X-OFF mode

1-6

Data bit

8-bit data

7-bit data

1-7

Parity check

No parity check

Parity check

1-8

Parity selection

Odd parity

Even parity

PP3000 Series User’s Manual