42

card; while

local type

is set as 2[H2355 account], set password. With

MGCP protocol used, please set domain name by this command. With

Net2phone system used, set password of Net2phone card by this command.

set registerport XXXX

Set register port.

According to used protocol, set as follows: With H323

protocol used, XXXX is ranged from 1024 through 6553; With MGCP

protocol used, please set is as 2427; With SIP protocol used, please set it as

5060; With Net2phone protocol used, this port could be any number.

set signalport XXXX

With H323 protocol used, signal port is Q.931 port using TCP protocol.

XXXX

is arranged from 1024 through 65535.

With SIP protocol used and

proxy

is stun, signal port is stun port by stun

Server specify or enter stun default port number 3478.

set controlport XXXX

Set control port. With H323 protocol used, this port is H.245 port using TCP

protocol. XXXX is ranged from 1024 through 65535.

register ttl :X

With H323 or SIP protocol, IP phone will send a keep-alive registration

message to H323 gatekeeper or SIP proxy server every “

register ttl

seconds. The minimum value is 10, maximum value is 255. Default is 60.

set rtptos X

Set TOS segment of IP head package in RTP digital follow.