Getting inside, Removing the nose, Etting – Pioneer 2TM User Manual

Page 69: Nside

Advertising
background image

ActivMedia Robotics

Remove the small plastic plug which is near the hinge on the top plate and near the

edge by the wheel. Under it, you will see the head of a large hex bolt. This bolt tightens
(clockwise) or loosens (counter-clockwise) the drive belt for that side of the robot. Turn it

using a 5mm hex key probably not more than 1 full rotation. Avoid over tightening.

Test to make sure that it is tight enough by holding the wheel while running the self test.
When adjusted satisfactorily, re-tighten the screws on the side and replace the plug.

G

ETTING

I

NSIDE

We normally discourage you from opening up your robot. However, on occasion, you

may need to get inside, for instance to access the user power connections on the Motor-
Power board and attach your custom electronics. Or you may need to get to your

onboard computer and its accessories.

Open the robot AT YOUR OWN RISK,

unless explicitly authorized by the factory.

REMOVE THE BATTERIES FIRST!

Figure 21. Remove indicated screws to

access front plate of Pioneer 2- and 3-DX

and -AT robots.

We describe here how to remove your robot’s nose to get at the onboard computer.

And we describe how to access the contents of the body of your Pioneer 3 and 2 DX or

AT robot.

Removing the Nose

The Pioneer 3- and 2-DX and –AT

onboard computer sits just behind the

robot’s nose. And you may have to
remove the nose to access the front

sonar array’s gain adjustment pot. Two

screws hold the nose to the front sonar
(or blank) array. The AT also has a screw

at the bottom of the nose that attaches

to the body; the DX’s nose is hinged at
the bottom.

Remove all nose retaining screws with the 3mm hex wrench supplied with your robot.

Unlike earlier Pioneer 2 models, you do not have to remove the Gripper or the front Bump
Ring accessories.

Once loosened, the DX nose pivots down on a hinge. For the AT model, four pins along

the nose’s back edges guide it onto the front of the robot. Simply pry the nose out and
away from the body.

63

Advertising
This manual is related to the following products:

3TM