Command descriptions, Ntconnnetwork connect, Ntconn network connect – Parker Hannifin GEM6K User Manual

Page 21: Ntconn

Advertising
background image

Command Descriptions








NTCONN

Network Connect

Type:

Network

Product Rev

Syntax:

<!><n>NTCONN<b>

Units:

n = network server #
b = Enable bit

Range:

n = 1-6
b = 0 (disconnect) or 1 (connect)

Default:

n = 1
b = 0

Response:

1NTCONN: *1NTCONN0

See Also:

ER, NTIP, [ NTS ], TER, TERF, TNTS, TNTSF

6K 5.3

The

NTCONN

command attempts the connection to the server (the server # is assigned with the

NTIP

command). If the

connection is successful, it will be reported to the user with the message “

CONNECTION SUCCESSFUL

” and Network Server

status bit #1 will be set (see

NTS

,

TNTS

, and

TNTSF

). If the connection is unsuccessful (e.g., attempting to connect to an

unspecified server #, or attempting to connect to a server in an incompatible subnet), then Error Status bit #23 is set to 1
(see

ER

,

TER

, and

TERF

) and the 6K transmits the error message “

NO NETWORK IP ADDRESS SPECIFIED FOR

CONNECTION, SEE NTIP

”.

Potential Error Conditions:

• If you attempt to connect to an Ethernet server before you enable Ethernet communication in the 6K with the

NTFEN

command, the 6K will not allow the connection and will transmit the error message “

ETHERNET

COMMUNICATION MUST BE ENABLED BEFORE MAKING CONNECTION - SEE NTFEN

”.

• If you attempt to execute an

NTIP

command attempt while the connection is open, the 6K will transmit the error

message “

NETWORK IP ADDRESS CANNOT BE CHANGED WHILE CONNECTION IS OPEN, SEE NTCONN

”.

• If there is a connection error, a polling timeout, error message from the server (etc.), the 6K will transmit the error

message “

CONNECTION ERROR, CONNECTION IS NOW BEING CLOSED

” and will also set Error Status bit #23 (see

ER

,

TER

, and

TERF

).

Example:
2NTIP1,172,54,125,34 ; Identify network server #2 as an Allen-Bradley PLC located at

; IP address 172.54.125.34

2NTCONN1

; Attempt connection to network server #2

2NTCONN0

; Close the connection to network server #2

page 17

Advertising
This manual is related to the following products:

6K