Outnetwork digital output, Out network, Digital output – Parker Hannifin GEM6K User Manual

Page 42: Network digital output, Use the, Page 38

Advertising
background image

\OUT

Network Digital Output

Type:

Network

Product Rev

Syntax:

<!>n\mOUT<b><b><b><b>
<!>n\mOUT.i-b

Units:

n = network server #
m = module #
b = enable bit
i = digital output # on module “m”

Range:

n = 1-6
m = 0-7
b = 1 (turn on), 0 (turn off), or X (don’t change)
i = 1-4

Default:

n\mOUT0000

Response:

n/a

See Also:

[ \OUT ], NTIO, \TIO, \TOUT

6K 5.3

n

\

m

OUT

b

b

b

b

Module # on Server “n”

(Range: 0-7)

Network Server #

(Range: 1-6)

Options for “b” are:

1 = Turn on
0 = Turn off
x = Don’t Change

Output #1

Output #2

Output #3

Output #4

Controlling Multiple Outputs

n

\

m

OUT

.i

-

b

Module # on Server “n”

(Range: 0-7)

Network Server #

(Range: 1-6)

Options for “b” are:

1 = Turn on
0 = Turn off
x = Don’t Change

Output Number

(Range: 1-4)

Controlling One Output

Use the

\OUT

command to control the state of each digital output on the OPTO22 unit.

The controller addresses the OPTO22 I/O locations as follows:

Each I/O bit is addressed by its location on a specific module. (NOTE: I/O points are not addressed by an absolute
32-bit location on the OPTO22.) Digital input and output modules have four I/O points, or channels, and are numbered
1-4. Analog input and output modules have two I/O points, or channels, and are numbered 1-2.

Digital

Input

Module

Input

1

0

Input

2

Input

3

Input

4

Digital

Input

Module

Input

1

1

Input

2

Input

3

Input

4

Digital

Output

Module

Output

1

2

Output

2

Output

3

Output

4

Digital

Output

Module

Output

1

3

Output

2

Output

3

Output

4

Analog

Output

Module

Output

1

4

Output

2

Analog

Output

Module

Output

1

5

Output

2

Analog

Input

Module

Input

1

6

Input

2

Analog

Input

Module

Input

1

7

Input

2

EXAMPLE: OPTO22 is Network Server #2

2\0IN.3

2\3OUT.2

2\5ANO.1

2\7ANI.2

Example:
2NTIP2,172,54,125,34 ; Identify network server #2 as an OPTO22 unit at IP address

; 172.54.125.34

2NTCONN1

; Attempt a connection to network server #2 (OPTO22 unit)

2\2NTIO2

; Server #2 (OPTO22), module #2 is a digital output module

2\3NTIO2

; Server #2 (OPTO22), module #3 is a digital output module

2\3OUT1001

; On Server #2, module #3, turn on Outputs #1 and #4 and turn off
; Outputs #2 and #3

2\2OUT.3-1

; On Server #2, module #2, turn on only Output #1

page 38