Nts ]network status, Ntselpnetwork program select enable, Network status – Parker Hannifin GEM6K User Manual

Page 32: Ntselp network, Program select enable, Ntselp

Advertising
background image

[ NTS ]

Network Status

Type:

Network; Assignment/Comparison

Product Rev

Syntax:

nTNTS<.i>

Units:

n = server #
i = bit number of status register (see table below)

Range:

n = 1-6
i = 1-8

Default:

n/a

Response:

n/a

See Also:

NTCONN, NTIP, NTPOLL, TNTSF

6K 5.3

Use the

NTS

operand to assign the Network Status bits to a binary variable, or to make a comparison against a binary or

hexadecimal value.

Syntax:

VARBx=

nNTS

where “

n

” is the network server number (e.g.,

VARB16=2NTS

). The

NTS

operand can also be used

in an expression such as

IF(2NTS=b11Ø1)

, or

IF(2NTS=h7F)

. To make a comparison against a binary value,

place the letter b (b or B) in front of the value. The binary value itself must only contain ones, zeros, or Xs (1, Ø,
X, x). To make a comparison against a hexadecimal value, place the letter h (h or H) in front of the value. The
hexadecimal value itself must only contain the letters A through F, or the numbers Ø through 9.
Bit Select Operation: Use the bit select operator (.) in conjunction with the bit number to specify a specific
Network Status bit. Examples:

VARB1=2NTS.3

assigns Network Status bit 3 for network server 2 to binary

variable 1;

IF(2NTS.3=b1)

is a conditional statement that is true if Network Status bit 3 for network server 2 is

set to 1 (polling is enabled).

Bit #

(left to right)


Function (1 = yes, 0 = no)

1

Connection Open.

2

Client Connection Error. This bit is set when a connection attempt with a server times out. This will
also set Error Status bit #23 (see ER, TER, TERF).

3

Polling Enabled. This bit is set when polling is enabled with NTPOLL.

4

Error during polling. This bit is set when an error during polling occurs. This will also set Error Status
bit #24 (see ER, TER, TERF).

5-8

Reserved

NTSELP

Network Program Select Enable

Type:

Network

Product Rev

Syntax:

<!>NTSELP<b>,<i>

Units:

b = enable bit
i = number of the integer variable (VARI) used for program
select

Range:

b = 0 (disable) or 1 (enable)
i = 1-225

Default:

b = 0 (disabled)
i = 1

Response:

NTSELP: *NTSELP0,1

See Also:

COMEXS, NTCONN, NTIP, NTMPRI, NTMPWI, NTPOLL, [ NTS ], TDIR,
TNTS, TNTSF

6K 5.3

The

NTSELP

command allows you to enable/disable the Network Program Select Mode, where, through the process of

exchanging integer data, an Allen-Bradley PLC can execute a 6K/Gem6K program by its number. Use the following
procedure as a guideline for implementing the Network Program Select mode:

1. Setup up Ethernet Networking with the Allen-Bradley PLC. This includes assigning the server connection (

NTIP

)

and connecting (

NTCONN

).

2. Use

the

NTMPRI

command to map at least one 6K variable to an Element in an integer data file in the PLC.

page 28