When you select SNMP Access Control, the system will display four blank fields for setting

(maximum of 4 SNMP devices can be set). Right-click on a blank in the list and click Edit Address.

The New/Edit Address dialog box will appear. Type in the IP address and set the password for the

SNMP device. There are two levels of access rights can be assigned:

Read: The user can read all information except the Access Control settings, but is not allowed to

alter anything.

Read/Write: The user can read and change all settings.

Please note do not set all SNMP devices in the table to Read only; otherwise the WAP-5100 is

impossible to be modified. The only solution is to reset the device back to factory defaults by using

Kick Start.

Trap Server

When the WAP-5100 is powered on, or an Ethernet port becomes active, an event log will be

generated indicating the time, the IP address of the reporting WAP-5100, and the event. You can

view and save the event logs from the station as a Trap Server. To assign a trap server, click Trap

Server tab.