102

7-8-5 MIC/AUDIO1

TEST TONE

NORMAL
ALWAYS
OFF
CHSEL

For selecting the test signal.
NORMAL: The test tone signal is output to all

the channels when the CAM/BAR
switch has been set to BAR and the
CH1 AUDIO IN switch has been set
to FRONT.

ALWAYS: The test tone signal is always output

to all the channels when the CAM/
BAR switch has been set to BAR.

OFF:

The test tone signal is not output.

CHSEL: The test tone signal is output to the

channels for which the CH1 or CH2
AUDIO IN switch has been set to
FRONT when the CAM/BAR switch
is set to BAR. It is not output to CH3
or CH4.

Item/

Data storage

Variable

range

Remarks

FRONT VR CH1

FRONT
W.L.
REAR
ALL
OFF

For setting whether or not to make the audio
control operational for the input system
selected for CH1.

FRONT VR CH2

FRONT
W.L. REAR
ALL
OFF

For setting whether or not to make the audio
control operational for the input system
selected for CH2.

MIC LOWCUT CH1

FRONT
REAR
W.L.
OFF

For selecting the microphone low-cut filter for
CH1.

MIC LOWCUT CH2

FRONT
REAR
W.L.
OFF

For selecting the microphone low-cut filter for
CH2.

LIMITER CH1

ON
OFF

For selecting the limiter for CH1.

LIMITER CH2

ON
OFF

For selecting the limiter for CH2.

CUE REC SELECT

CH1
CH2
CH1+CH2

For selecting the signals to be recorded for
the CUE channel.

TYPE A

2

/

11.0

:

13.5

:

15.0

12.0

:

15.0

:

17.0

For enabling or disabling the selection made
for the BATTERY SELECT item.

2

: The selection is enabled.

/ : The selection is disabled.

For selecting in 0.1 V steps the voltage at
which the battery charge is to be considered
nearly depleted.

For selecting in 0.1 V steps the voltage at
which FULL is to be displayed.

11.0

:

11.9

:

15.0

For selecting in 0.1 V steps the voltage at
which the battery charge is to be considered
depleted.

Item/

Data storage

Variable

range

Remarks

TYPE B

2

/

11.0

:

13.1

:

15.0

12.0

:

15.5

:

17.0

For enabling or disabling the selection made
for the BATTERY SELECT item.

2

: The selection is enabled.

/ : The selection is disabled.

For selecting in 0.1 V steps the voltage at
which the battery charge is to be considered
nearly depleted.

For selecting in 0.1 V steps the voltage at
which FULL is to be displayed.

11.0

:

12.6

:

15.0

For selecting in 0.1 V steps the voltage at
which the battery charge is to be considered
depleted.

NEAR END

FULL

END

NEAR END

FULL

END

C U F

C U F

C U F

C U F

C U F

C U F

C U F

C U F

C U F

C U F