Profoto Pro-7 User Manual

Page 17

Advertising
background image

Pro-7a 1200/2400

Energy Distribution

When only one lamp head is in use, choose the A socket. Only

the A socket can be used to release the generator’s total energy

to one lamp head. Use dial A to adjust energy in 1/3 f:stop

increments from full (1/1) down to (1/8) energy, which is

equivalent to four [4] f:stops.

PLEASE NOTE ! When the dial is positioned to release more

than 1/2 energy (within the area marked A ONLY) always

point the dial B towards the red indicator [16]. If this is not

done, the indicator lamp will light up. The audible signal will

sound and flash release will not be possible. When the dial is

pointed within the ”A ONLY” area, the flash is only released to

the lamp head connected to socket A, even if other lamp heads are connected to the B sockets.

When a second lamp head is connected to socket B1 use dial B to adjust energy in 1/3 f:stop

increments, from half energy (1/2) down to one sixteenth energy (1/16), which is equivalent to

four [4] f:stops. When the dial is pointed within the B1 ONLY area, the flash will not be released

through B2 even if a lamp head is connected.

PLEASE NOTE! To release a flash through B socket(s) dial A must be pointed to less than 1/2

energy. If not, an audible signal will sound and the red lamp [16] will light up at the B dial 1/2

position. When a third lamp head is connected to socket B2 use dial B to adjust energy in 1/3 f:stop

increments from one quarter energy (1/4) down to one sixteenth energy (1/16). The B1 lamp head

will follow i.e. when the B dial is positioned for 1/8 energy B1 and B2 will both receive 1/16

energy.