Pro-7s 1200/2400

27

Mains Connection

Use the included power cable to connect to the mains power supply. The generator can be

connected to all common mains voltages 90-240V and 50-60Hz. The generator automatically

senses which voltage range is supplied. The green lamp below the handle indicates that the

generator is receiving power from the mains. If not check the mains fuse for faults.

(Please also see ”Gas Generator” on page 32).

Warning: Never use ordinary household extension cords to elongate the power cable.

• Connect the generator to the mains supply with the enclosed power cable [1]. The green

lamp [3] should now light up indicating acceptable AC current to the generator.

• Connect the lamp head(s) to the socket(s) [2].

• Use the control MOD. LIGHT [12] to choose modelling light mode.

• Press the button [4] ON to start charging. The white ready lamp [9] flashes the first time

the generator is charged indicating that ”dumping” of energy is needed.

• Choose the desired energy output with the ENERGY control [5]. For full energy choose 1/1.

• Press the test button [9] to dump the energy. The generator is now charged to the chosen

energy and the white ready lamp/test button [9] will light up.

• Connect sync cord and/or flash meter to the sync sockets SYNC [7].

• Activate the photo/IR-cell [6] by pressing the button SLAVE [8].

• Activate the audible signal by pressing the button SOUND [10].

• For normal recharging speed, press the FAST [11] button.

Brief Instructions

Pro-7s 1200/2400 Generator