Changing Battery

By putting the two handles at the bottom together the battery

cassette is released and the battery can easily be pulled out. A

new battery is pushed all the way into the generator and is

locked by directing the handles away from each other. When

changing the battery it must be mounted in a battery cassette

by an authorised service station. If the battery is not pur-

chased at Profoto a Hitachi HV 12 -12 unit must be used.

Connecting Lamp Heads

One or two lamp heads can be connected to the lamp head

sockets A & B [1]. When connecting the lamp head plug,

align the dots on the plug with the white dot on the generator

panel. Secure by turning the locking ring on the plug clockwise.

Energy Control

The energy output is regulated over seven f:stops. The energy

can partly be adjusted with the control MASTER [13] in 1/6

f:stop increments, from 1/1 down to 1/16 of the total energy

(equivalent to five f:stops) partly with the SYM/ASYM

switch [2] through one or two lamp heads.

One lamp head: The total energy chosen is obtained if the

lamp head is connected to A and the SYM/ASYM switch is at

A 1/1(1/2), B 1/2. The lamp head can be connected to socket A

or B. If the lamp head is connected to A the total energy is

obtained chosen with the control MASTER [13]. If the lamp

36