Profoto Pro-7 User Manual

Page 32

Advertising
background image

32

Pro-7s/1200

Pro-7s/2400

Guide numbers in metres/feet at 100 ASA

with a Magnum 50° Reflector

140

201

Flash Duration (t 0.5) at:

Pro-7 head

Pro-7 twin

Pro-7 head

Pro-7 twin

4800 Ws

1/1600 sec.

2400 Ws

1/2200 sec.

1/1600 sec.

1/2200

1200 Ws

1/2200 sec.

1/3200

1/2200

1/3200

600 Ws

1/3200

1/5300

1/2700

1/4500

300

Ws

1/4500 1/6800 1/3200 1/5300

150

Ws

1/5300

1/8000 1/5300 1/8000

75 Ws

1/8000

1/12000

1/5300

1/8000

37,5 Ws

1/8000

1/12000

1/8000

18.75 Ws

1/12000

PLEASE NOTE: With Pro-7 twin and two Pro-7s generators the recharging time is approx. twice as fast.

Recharging Time at:

230V/50Hz

0.08 - 0.8 sec.

0.12 - 1.5 sec

120V/60Hz

0.10 - 0.9

0.14 - 1.6

200V/50Hz

0.08 - 1.1

0.12 - 2.1

100V/50Hz

0.14 - 1.6

0.18 - 2.9

Power Consumption (Turbo)

200 - 240V, 50/60Hz

10 A (fuse)/generator

100 - 120V, 50/60Hz

15 A (fuse)/generator

Maximum Modelling Light

Maximum 500 W per head or totally 1500 W when three heads are used. Please note that the

modelling light output automatically adjusts itself to the voltage in question (100 - 240V).

Size & weight, generators

Pro-7s/1200

Pro-7s/2400

Width x length x height cm/in

24 x 17 x32

24 x 17 x 40

9

1

/

2

x 6

3

/

4

x12

9

1

/

2

x 6

3

/

4

x 15

3

/

4

Weight, kg/lb

9 / 20

12 / 26

Size weight, lamp head

Length (incl. glass

26 x 10 cm

cover) x diameter, cm/in

10” x 4”

Weight, kg/lb

2.4 / 5

Gas Generator

Most gas generators with an output of 3000 W or more can always power Profoto generators.

Please note that you always need a ProGas unit between the gas generator and the Profoto gen-

erator in order not to damage these two units (only 230V). For more information please contact

your local dealer.