Drill six 1/2" holes through drywall and metal studs.

NOTE: It may be necessary to drill 5/32" pilot holes prior to

drilling 1/2" holes.

Refer to instruction sheet included with Peerless accessory kit ACC 615 for metal studs to install togglers.

Fasten two 1/4-20 x 2-1/2" screws into top mounting holes leaving a .25" of exposed thread on each as shown in
fig. 2.4. Hook wall mount assembly (A) onto 1/4-20 x 2-1/2" screws.

Fasten four

1/4-20 x 2-1/2" screws

into wall mount assembly (A) as shown in fig. 2.5.

Make sure that the wall mount

assembly (A) is level, tighten all six 1/4-20 x 2-1/2" screws.

• Drywall must be 1/2" or thicker, and metal stud must be 24 gauge or thicker.

• Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached

hardware and components.

WARNING

Installation to Metal Stud Wall (Metal Stud Accessory Kit ACC 615 Required)